© 2010 Veriteq Instruments Inc.
To save configuration settings:
1
From the vNet Configuration and Management interface,
choose
Utilities | Backup/Restore
.
2
Select the
Backup
tab and click
Backup
.
3
At the
File Download
prompt, click
Save
.
4
Choose a location where you want to save the file and
specify a file name. The default file name is
vNetConfigBackupXXXXXXXX
(X denotes the 8-digit
serial number of the vNet device).
5
At the
Download Complete
prompt, click
Close.
Device-
Name
The device name that will be shown in the Digi
Device Discovery software. It can be up to 63 charac-
ters in length.
Contact
An informational description that is saved in the vNet
device. It can be up to 63 characters in length.
RealPort
The TCP port number that the RealPort driver will use
to access the serial port on the vNet device.
RawPort
The TCP port number that the Raw TCP driver will use
to access the serial port on the vNet device.
EnableFan
The control setting for the vNet device fan. Valid val-
ues are
on
or
off
.
Enable15V
The control setting to enable or disable the 15V loop
power supply output. Valid values are
true
or
false
.
Item
Configuration
Table 1: Configuration Backup File