24
© 2010 Veriteq Instruments Inc.
Enabling 15V Loop Power Excitation
The Veriteq vNet device may include a 15V loop power
output, which allows you to provide power to a sensor or
transducer connected to a Veriteq data logger recording 4-20
mA currents or DC voltage signals.
If your vNet device is equipped with this feature, the option to
enable or disable loop power displays on your screen.
To enable or disable 15V Loop Power Excitation:
1
From the vNet Configuration and Management interface,
choose
Management | Power
.
2
In the Power Settings screen, check or uncheck the
Enable 15V Loop Power Excitation
checkbox to enable
or disable loop power.
3
Click
Apply
.
Backing Up or Restoring Configuration Set-
tings
We recommend you save your current vNet device
configuration settings to a backup file so they can be restored
at a later time. You can also use this backup file to configure
another vNet device.
When restoring settings from a configuration backup file that
was created by a different vNet device, consider the
following:
• The configuration backup file is a plain text file that can be
edited.
• You can remove items from the configuration backup file if
you do not want to change their settings (such as NetBIOS
name).