29
Installation manual auroTHERM 0020100606_02
1
2
3
4
Fig. 5.23 Fitting the hydraulic connections (1-5 collectors)
Procedure for a horizontal row of up to
5 collectors.
>
Connect the flow line (outlet with opening
for collector sensor) (
1
) at the top on one
side.
>
Connect the return (inlet) (
2
) at the bot-
tom.
>
Fit the two plugs with bleed openings at
the top and bottom of the collector on
the other side of the collector array
(
3
and
4
).
>
Secure the connections and plugs with
the clips.
>
Connect the collector flow and return
lines to the system with the connecting
pipes.
>
Perform the previously listed steps for all
horizontal rows.
After assembly of all rows:
>
Remove the red plug from the outlet on
the uppermost row of the collector array.
>
Insert the collector sensor into the open-
ing.
>
Use a cable tie to prevent the collector
sensor from slipping out.
1
2
3
4
Fig. 5.24 Fitting the hydraulic connections (6-12 collectors)
i
If you connect 6 or more collec-
tors one after another, the hydrau-
lic connections must be arranged
diagonally, to force a complete
flow.
Procedure for a horizontal row:
>
Fit a plug with bleed opening (
1
) on one
side at the top.
>
Insert the return line (inlet) (
2
) into the
lower opening at the side.
>
Insert the flow line (outlet with opening
for collector sensor) (
4
) into the upper
side opening diagonally opposite.
>
Fit a further plug with bleed opening (
3
)
at the bottom.
>
Secure the connections and plugs with the
clips.
>
Connect the collector flow and return lines
to the system with the connecting pipes.
>
Perform the previously listed steps for all
horizontal rows.
Assembly 5