Installation manual auroTHERM 0020100606_02
For all other arrangements (VFK H/V)
a
A
B
2
1
3
Fig. 5.21 Hydraulic connection
>
Insert the pipe couplers (
¬ Table 5.1/5.3,
Item 6
) into the side openings in the col-
lector until the end stops are reached (
1
).
>
Secure the pipe couplings with the
clips (
2
).
b
Caution!
Danger of damage to the
collectors!
The flat collector can be damaged
if the pipe coupler is not fitted cor-
rectly.
>
Make sure that the clip (
A
)
slides into the slot in the pipe
coupler (
B
).
a
Danger!
Risk of death caused by
improper assembly!
If not fixed properly, the flat col-
lector can fall off and endanger
persons.
>
After fixing each collector,
check that all screwed connec-
tions are tight and retighten
them if necessary.
5.5.5 Fitting the remaining vertical collector rows
>
Before assembling the next vertical row, lay down the
collectors as described in Chapter 5.6.2.
>
Fit the required front section in front of the collectors
(
¬ Chapter 5.5.3, Fig. 5.10
).
a
Danger!
Risk of death caused by improper
assembly!
If not fixed properly, the flat collector can fall
off and endanger persons.
>
After fixing each collector, check that all
screwed connections are tight and
retighten them if necessary.
b
Caution!
Leaks caused by inaccurate mounting
position!
Leaks can occur in the cover plates for roof
integration if the mounting position of the
collectors is not precise.
>
Using a spirit level, make sure that the col-
lectors are sitting horizontally and are rest-
ing flush with one another.
>
Make sure that the distance between the
collectors is 30 +/- 1 mm.