Installation manual auroTHERM 0020100606_02
32
2
1
Fig. 5.28 Fastening the shorter top side sections
>
Remove the film from the short side sec-
tions.
>
Slide the short side sections
(
¬ Table 5.1/5.3, Item 22/23
) over the
collectors at the left and right in the
uppermost horizontal row.
>
Take care that the respective side section
– rests on the collector frame,
– is pushed together with the lower side
section at the fold (
1
). Push the fold on
the lower side section apart a little for
this.
>
Press the side section on to the side sec-
tion so that it locks.
>
Fasten the side sections to the roof bat-
tens with the supplied brackets (
2
)
(
¬ Table 5.1/5.3, Item 31
) and No.
2
screws (
¬ Table 5.2/5.4
) using the Torx
bit.
5.5.7 Attaching trapezoidal plates, connectors,
ridge sheets and tile supports
4,5
2
3
1
Fig. 5.29 Attaching the ridge plates
The trapezoidal plate (
1
) (
¬ Table 5.1/5.3,
Item 27
) covers the area (the "cross") in
which the interstices of four collectors meet.
>
Slide a trapezoidal plate with the strap
under the vertical intermediate plate (
1
).
>
Slide the trapezoidal plate forward until
the bent edges rest on the horizontal
intermediate plates.
>
Drill a hole through the opening at the
upper end of the trapezoidal plate into the
intermediate plates underneath (
2
).
>
Rivet the trapezoidal plate to the interme-
diate plates (
3
).