4 Interconnection
scheme
i
Observe the planning information when
dimensioning the flow rate for the array.
>
Connect up the flat collectors using the following
rules:
1
3
4
2
Fig. 4.1 Direction of flow
You can connect the flat collectors hydrauli-
cally in four different ways, as shown in the
illustration.
However the direction of flow is always from
bottom to top.
1
4
5
...
Fig. 4.2 Series connection of 1 - 5 flat connectors
If you connect 1 to 5 collectors one after
another, the hydraulic connections can be
laid one below the other on one side.
1
12
11
2
...
max. 12
Fig. 4.3 Series connection of 6 - 12 flat connectors
If you connect 6 to 12 collectors one after
another, the hydraulic connections must be
arranged diagonally, to force a complete flow.
Installation manual auroTHERM 0020100606_02
8
4 Interconnection scheme
Содержание auroTHERM VFK 145/2 H