Installation manual auroTHERM 0020100606_02
20
5.5.3 Fitting the front sections
>
Fit the front sections in each case at the start of a
vertical collector row.
>
Keep exactly to the sequence described here when
doing so.
w
For the horizontal collector position you will
require two front sections for each vertical
row.
s
For the vertical collector position you will
require one front section for each vertical row.
a
Caution!
Leaks caused by inaccurate mounting
position!
Leaks can occur in the collector system if the
framework parts are not assembled precisely.
>
Make sure that the fold on the front sec-
tion rests flush on the roof batten.
>
With the help of a spirit level, make sure
that the front section is resting horizontally
on the roof batten.
5.5.3.1 Left hand front section
1
Fig. 5.10 Attaching the left hand front section at the bottom
>
Pick up the left hand front section
(
¬ Table 5.1/5.3, Item 33
).
>
Fit the left hand front section of the frame
to the 2nd roof batten viewed from below.
The front section will thus rest on the low-
est roof batten (the previously fitted addi-
tional roof batten).
>
Leave the protective film on the adhesive
surface of the flexible apron.
>
Let the flexible apron rest on the roof tiles
and push the left hand edge of the apron
between the tiles.
>
Screw the front section to the roof batten
with 6 No.
1
screws (
¬ Table 5.2/5.4
)
using the Torx bit, as shown in (
1
).
s
Only for the vertical collector position
>
Continue with the assembly of the vertical collector
row.
w
Only for the horizontal collector position
>
First attach the second front section as described in
the following.
5 Assembly
Содержание auroTHERM VFK 145/2 H