25
Installation manual auroTHERM 0020100606_02
Fig. 5.17 Fitting the next collector
>
To fit the next collector, first remove the
additional roof batten with which you pre-
viously secured the collector(
¬ Fig. 5.9,
Chapter 5.5.2
).
>
Once you have removed the additional
roof batten, let the collector slide down
slowly until it is resting on the spacer.
b
Caution!
Leaks caused by inaccurate
mounting position!
Leaks can occur in the cover
plates for roof integration if the
mounting position of the collectors
is not precise.
>
Take care that the spacer
-
is resting flush at the side
on the inner edge of the
collector,
-
terminates at the ends in
line with the inner edge
of the collector.
>
Using a spirit level, make sure
-
that the collectors line
up above one another,
-
that the collector is lying
horizontally.
1
2
Fig. 5.18 Screwing the flat collectors
>
Screw the collector firmly to the roof bat-
tens with 2 of the supplied brackets
(
¬ Table 5.1/5.3, Item 31
) and No.
2
screws (
¬ Table 5.2/5.4
)
on each side
using the Torx bit.
The folded side (
1
) of the clamp must point
away from the collector.
>
Take care that the chamfered side (
2
) of
the clamp grips the edge of the collector.
>
Fit the collectors for the entire vertical row in the
manner previously described (
¬ Figs. 5.12 to 5.18
).
>
Then make the hydraulic connections as follows.