9
Troubleshooting
PROBLEM
POSSIBLE SOLUTION
PAGE
Lid will not open or is
very slow to open
Ensure all cycles are complete
Adjust cycle times if necessary
Check solenoid valve
19
Check control solenoid valve
21
Check piston
14
Check silicone tubing
Check circuit board
18
Pump starts while lid is
still open
Check microswitch
17
Check circuit board
18
LP error is showing
Check fuse
10
Check power cord
Check transformer
18
CLO error is showing
Check silicone tubing for leaks
Check control solenoid valve
19
Check solenoid valve
20
Check circuit board
18
Содержание 186VMC16F
Страница 22: ...22 Wire Diagram for VMC16F ...
Страница 23: ...23 Wire Diagram for VMC20F ...
Страница 24: ...24 Wire Diagram for VMC20FGF ...