![VacPak-It 186VMC16F Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/vacpak-it/186vmc16f/186vmc16f_service-manual_847748012.webp)
12
Part Replacement Continued
Testing: Visually look for marks and cuts to tape on
bar
Visually ensure bar is clean of debris
Continuity between post mount locations
(Fig.
12)
Replace:
if marks and cuts are found on the
outside
if no continuity is found between
post mount locations (Fig. 12)
Time Estimate: Approximately 5 minutes
Part: #186PSEALBAR3 (186VMC16F ONLY)
#186P20FSB (186VMC20F ONLY)
#186P20FGFSB (186VMC20FGF ONLY)
1. Follow pre-maintenance steps from page 10
2. Lift sealing bar up from mounting tabs (Fig. 13)
3. Reverse steps to install
Sealing Bar
Fig. 13
Fig. 12
Time Estimate: Approximately 20 minutes
Part: #186PLID20
1. Follow pre-maintenance steps from page 10
2. Remove Phillips head screws from rear panel
Note: 11 screws on 186VMC16F, 8 screws on
186VMC20F and 186VMC20FGF
3. Remove mounting bolt and nut using a Phillips head
screw driver on the outside and a 6mm socket on the
inside
4. Installation is the reverse of the removal steps
Lid Latch Assembly
Содержание 186VMC16F
Страница 22: ...22 Wire Diagram for VMC16F ...
Страница 23: ...23 Wire Diagram for VMC20F ...
Страница 24: ...24 Wire Diagram for VMC20FGF ...