8
Troubleshooting
PROBLEM
POSSIBLE SOLUTION
PAGE
Bags are not sealing
Adjust sealing time cycle
5
Ensure pouches are laying flat on sealing bars
6
Ensure sealing bars are clean
7
Ensure pouch has no wrinkles
6
Check sealing foam
11
Check solenoid valve
19
Check piston
14
Check circuit board
18
Unit is making an extra
loud noise when running
Check pump site gauge fluid level
4
Check lid sealing gasket
11
Check vacuum silicone tubes
Check pump
15
Bags are not being fully
vacuumed
Check pump site gauge fluid level
4
Adjust vacuum cycle time
5
Check lid
11
Check lid sealing gasket
11
Check voltage is getting to the pump
15
Check solenoid valve
19
Check main circuit board
18
Front circuit board does
not come on
Ensure correct power is supplied
Ensure unit is plugged in
Check to see if fuse is blown
10
Check switch for voltage and function
15
Check front circuit board
13
E01 error is showing
Ensure lid was held down to start
6
Check lid
11
Check lid sealing gasket
11
Check microswitch
17
Vacuum cycle does not
start
Ensure unit is plugged in and turned on
Ensure lid is closed
4
Adjust vacuum cycle time
5
Ensure cycle time setup has been exited
5
Check microswitch
17
Check main circuit board
18
Содержание 186VMC16F