![VacPak-It 186VMC16F Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/vacpak-it/186vmc16f/186vmc16f_service-manual_847748016.webp)
16
Part Replacement Continued
Time Estimate: Approximately 30 minutes
Part: #186PSTRUT2 (186VMC16F only)
#186PSTRUT3 (186VMC20F and
186VMC20FGF)
1. Follow pre-maintenance steps on page 10
2. Remove Phillips head screws from rear panel
Note: 11 screws on 186VMC16F, 8 screws
on 186VMC20F and 186VMC20FGF
3. Remove hex nut from lower Lid Strut mount-
ing tab with a 7mm socket (Fig. 26)
4. Remove Lid Strut from lower mounting post
by pulling away from mount arm
Continued on page 17
Lid Strut
4. Remove 3 hex nuts with a 14mm socket from under the
machine for the mounting post legs for the pump (Fig. 24)
5. Disconnect the power wires going to the Main Circuit
board (Fig. 25 - B)
6. Remove Phillips head screw that is securing the
ground wire terminal (Fig. 25 - A)
7. Remove wiring and pump from inside machine
8. Installation is reverse of removal steps
Fig. 24
Fig. 25
A
B
Fig. 26
Содержание 186VMC16F
Страница 22: ...22 Wire Diagram for VMC16F ...
Страница 23: ...23 Wire Diagram for VMC20F ...
Страница 24: ...24 Wire Diagram for VMC20FGF ...