Part Replacement Continued
Time Estimate: Approximately 20 minutes
Testing : Good = Continuity through wire connection
Bad = No continuity through wire connection
Part: #186P16FSV
1. Follow pre-maintenance steps on page 10
2. Remove Phillips head screws from the rear panel of
the machine
Note: 11 screws on 186VMC16F, 8 screws on
186VMC20F and 186VMC20FGF
3. Disconnect wires from main circuit board and note
location (Fig. 33)
4. Remove Phillips screw from plastic clamp holding
tubing and valve down (Fig. 34)
5. Remove poly tubing from either side of the valve by
pulling them away from the center of the valve (Fig. 35)
6. Installation is reverse of removal steps
Small Solenoid Valve
Fig. 33
Fig. 34
Fig. 35
3. Remove wires connected to the main circuit board,
note locations
4. Remove 4 Phillips head screws from each corner of
the main circuit board and remove board
5. Installation is reverse of removal steps