1-48
GS-4000
LogoMaster
Command Dispatcher has the ability to perform multiple actions from one trigger, and
more events can be added in the same manner to the list on the right and all be tied to the
same trigger value. It is possible to also set a delay between events by using the Generic
Client in the “Select Client” drop down menu:
Figure 1-29.
Add Event
To store all configuration settings (including server settings and triggers) the “Save
Settings” button within the main window can be used to save out a *.proc file. This file can
then be loaded in the future with the “Load Settings” button to restore that configuration.