19
Install Actuator Mounting Tube - PUSH TO OPEN (PRO80 or HD)
Cut Actuator Mount Tube to proper length. Weld to support bracket.
(
See table below for desired dimensions.)
The actuator mounting tube will need to be cut so that the ⅜” hole location matches the dimensions
for a push to open system.
IMPORTANT: Verify the actuator type (PRO80 or HD) paying attention to the dimensions in the
chart below.
Before welding in place, ensure the actuator
mounting tube is level in all directions and ⅜”
pivot hole location on actuator mounting tube is at
proper point per the dimension chart for the type of
installation being performed.
Dim A
Dim B
Cut Line
PUSH TO OPEN - Actuator Hinge Mounting Tube Installation Dimensions
Gate opening in degrees
Ranger HD
Dimension A
Ranger HD
Dimension B
Ranger Pro80
Dimension A
Ranger Pro80
Dimension B
90 degree opening
11”
6”
7”
4”
100 degree opening
13”
6”
8.5”
4”
110 degree opening
14.5”
6”
6b
* Dimensions shown are
for 90° - 95° opening.
Dim A
Dim B