This Ranger Gate Operator is intended to be installed on the four
different classes of gate operators identified in the UL325 Standards.
RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I
A vehicular gate operator (or system intended for use in garages or parking areas associated with a
residence of one-to four single families.
COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR – CLASS II
A vehicular gate operator (or system) intended for use in a commercial location or building such
as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other
buildings accessible by or servicing the general public.
INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR – CLASS III
A vehicular gate operator (or system) intended for use in an industrial location or building such as a
factory or loading dock area or other locations not accessible by or intended to service the general
public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR – CLASS IV
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such
as an airport security area or other restricted access locations not servicing the general public, in
which unauthorized access is prevented via supervision by security personnel.
Solar Friendly
The system design and the accessories recommended are all Solar Friendly meaning that they
require the least amount of energy possible to perform the job they were designed to do. The solar
option allows you to install the gate operator in remote areas or in applications where you prefer to be
solar charged. Solar charging provides additional isolation from lightning that might damage the unit
via the AC power needed for the transformer.
BATTERY REQUIRED FOR OPERATION
(Battery not included)
Recommended battery type:
Battery 12-volt, Group U-1; sealed (maintenance free); 30 amp hour minimum.
Using a smaller amp hour battery may cause damage to the charging system.
The wiring harness has two 1/4” ring terminals to connect to battery posts.
CAUTION
: Do not install wet cell battery into control box; this type of battery
usually has removable caps used for service and will vent into control box.
The battery is charged using the 120V DC Adaptor (PN #520009)
OR
the Solar Panel kit (PN
520026). For information on what you can expect from a solar charged system see the solar charging
section of this manual.
PLEASE READ THE ENTIRE MANUAL CAREFULLY PRIOR TO INSTALLATION.
Study the entire Safety Section paying particularly close attention to the entrapment zones and
install monitored entrapment devices to protect all entrapment zones identified. Installation by a
Qualified Technician is recommended to verify all safety concerns are addressed.