4. All cutting teeth must be of equal length
5. Always completely file away any damage
Areas on side plate and top of tooth.
The chain supplied with the saw is to be sharpened at the following angles:
Hold file holder at a 10° upward tilt
Chain Repair
Shortening and lengthening the chain
(Chain added between two left-hand cutting teeth)
(Two coupling links and one drive link between cutting teeth)
Most chain saws are assembled with one coupling link between a right-hand and a left-hand cutting
tooth, however there are also chains which are assembled differently due to their length (number of
drive links). If a chain must be shortened or lengthened, it is best to do so at this point. However do
not insert more than two coupling links between two cutting teeth.
Important:
When shortening the chain, always remove the standard drive link and not the
safety
l
ink.
side plate