29
3
SCREENS AND OPERATIONS
29
SCREENS AND OPERATIONS
Chapter
3
Result display :
The result is displayed.
The waveform comparison and the hold results of each section are displayed
overall according to the priority.
* The displacement result is not displayed if X axis is time.
Indicated value display:
Displays the indicated value selected by
(digital value of the load sensor/
displacement sensor input), and also displays load sensor/displacement sensor errors.
* When the indicated value selected by
is Section 1 - 5, if there is no hold
value, “-----” is displayed.
Work display:
Displays the present work No. specified by external input “Work.”
Selected indicated value display:
Displays the currently-selected indicated value.
Present
........ Present value
1
................... Section 1
2
................... Section 2
3
................... Section 3
4
................... Section 4
5
................... Section 5
Keys
: Moves to a result screen.
There are two types of screens: [Result (Single)] and [Result (List)].
In moving from the Main screen, the previously displayed screen appears.
(The default display is [Result (Single)].)
: Moves to the Wave Check screen.
: Moves to the Setting screen.
: Simply makes the same movement as the Reset signal.
Also, when the error display appears, this key clears it after release.
: Simply makes the same movement as the Start signal.
This key is valid when the status display is Complete or Wait St.
When pressed, it changes to
.
Priority
Result
Judgment condition
1
H/L
HI/LO limit over (HI limit over and LO limit over)
2
HI
HI limit over (judgment point > HI limit set value)
LO
LO limit over (judgment point < LO limit set value)
3
NG
<Hold operation>
- Measurement did not reach the section.
- Failure to detect the judgment point.
* If the setting is such that Start Point of Section n = End Point of
Section n = Start Point of Section n+1, the result of the present
section is always “NG.”
<Waveform comparison operation>
- Measurement did not reach the Compare Area.
- Measurement did not reach the Reference Point of Relative
Comparison when Relative Comparison is made.
4
OK
Normal (LO limit set value
≦
Judgment point
≦
HI limit set value)
Содержание DeviceNet F381A
Страница 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Страница 9: ...Contents VIII Contents VIII M E M O ...
Страница 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Страница 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Страница 164: ......