83
5
COMMUNICATIONS
83
CO
MM
UNICATIO
NS
Chapter
5
■
Communication method (when the Communication Mode is Normal)
By transmitting commands from the host, operations corresponding to the commands are executed.
-List of items that can be communicated
Item group
Set value, operation,
display item
Read
Write
Cal.
Reference
Main
Load (display)
〇
×
×
Display read command
DPM (display)
〇
×
×
Display read command
Work No. (display)
〇
×
×
Display read command
Measurement status
display
○
×
×
Display read command
Waveform update check
〇
×
×
Waveform update check/
equipment ID read
command
Measurement waveform
〇
×
×
Waveform read command
Equipment ID
〇
×
×
Waveform update check/
equipment ID read
command
Result
Result (display)
〇
×
×
Hold result read
command
Result
〇
×
×
Result read command
Wave No.
〇
〇
×
Wave No. read/wave No.
write command
First Setting
Y-axis Setting
Exc. Voltage
〇
〇
×
Set value read/
set value write command
Unit
〇
〇
×
Set value read/
set value write command
Decimal Place
〇
〇
×
Set value read/
set value write command
Zero Cal.
〇
×
〇
Set value read/
Zero cal. command
Equiv. Cal.
(rated output)
〇
〇
×
Set value read/
set value write command
Equiv. Cal.
(rated capacity)
〇
〇
×
Set value read/
set value write command
Actual Cal.
×
×
〇
Actual cal. command
Overload
〇
〇
×
Set value read/
set value write command
Increment
〇
〇
×
Set value read/
set value write command
Analog Filter
〇
〇
×
Set value read/
set value write command
Digital Filter
〇
〇
×
Set value read/
set value write command
DZ Limit
〇
〇
×
Set value read/
set value write command
Содержание DeviceNet F381A
Страница 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Страница 9: ...Contents VIII Contents VIII M E M O ...
Страница 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Страница 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Страница 164: ......