UniPOS
Interactive Fire ControlPanel IFS7002
Instruction Manual
Page
37
Revision 2.05
Of 107
♦
Detector contamination, in percentage, against the maximum permissible
contamination value;
♦
Status of the detector’s isolator – Off (no response) or On (responded);
♦
LED status – Off (not illuminated/ not flashing) or On (illuminated);
♦
Information for the level of detector contamination– the text message
Contaminated
appears only if the fire detector is contaminated and needs cleaning;
♦
Information for Fire condition – the text message
Fire Alarm
appears only when the
detector responded;
♦
Information for Pre-alarm – the text message
PreAlarm
appears only if the smoke
concentration value is near the response threshold for fire condition;
♦
Information for Fault condition – the text message
Fault
is displayed only when the fire
detector responded to a fault condition;
−
For conventional line-monitoring modules with heat detector FD7201:
♦
The current value measured in the conventional fire alarm line, connected with the
module;
♦
Information for fire condition in the conventional line – the text message
Fire Alarm
appears only when a detector in the conventional line responded;
♦
Information for short circuit in the conventional line – the text message Short appears
only if short circuit is detected in the conventional line;
♦
Information for fault condition: break in the conventional line – the text message
Open
appears only if a break in the conventional line is detected;
♦
Information for fault condition: removed fire detector in the conventional line – the text
message
Removed FD
appears only when a conventional line detector is removed;
♦
The temperature in the module, measured by the fire detector, in Celsius;
♦
Temperature class of the detector in the module;
♦
Status of the detector’s isolator – Off (no response) or On (responded)
♦
LED status – Off (not illuminated/ not flashing) or On (illuminated);
♦
Information for Fire condition – the text message
Fire Alarm
appears only when the
heat detector in the conventional line-monitoring module responded or when a fire
detector in the conventional line responded;
♦
Information for fault condition – the text message
Fault
appears only if the
conventional line-monitoring module detected a fault condition;
−
For input/output modules FD7203:
♦
Outputs switched on – a list of switched on outputs, designated „Rel1” to „Rel6”, or the
text message
None
appears if no outputs are switched on;
♦
Input status – „0” (no input signal) or„1” (input signal);
♦
Status of the isolator of the module at the power supply loop – Off (no response) or
On (responded);
♦
Status of the isolator of the module – Off (no response) or On (responded);
♦
LED status – Off (not illuminated/ not flashing) or On (illuminated);
♦
Information for fault condition – the text message
Fault
appears only if the module
detected a fault condition
−
For single output modules FD7204:
♦
Status of the output –
On
or
Off
;
♦
Status of the isolator of the module at the power supply loop – Off (no response) or
On (responded);
♦
Status of the isolator of the module – Off (no response) or On (responded)
♦
LED status – Off (not illuminated/ not flashing) or On (illuminated)
♦
Information for fault condition – the text message
Fault
appears only if the module
detected a fault condition.