Programming setting
54
ADJ SOND
FUMI
M-8- 7
23°C
7.8.8 - Submenu 08 - 08 alarm reset
Cancels the memory of the latest alarms triggered.
Accessible only with password.
7.8.9 - Submenu 08 - 09 counter memories
By pressing the keys 6 and 5, the following memory records are displayed in sequence:
•
Total hours
•
Partial hours
•
Number of starts
•
Alarm log 1
•
Alarm log 2
•
Alarm log 3
•
Alarm log 4
•
Alarm log 5
7.8.10 - Flue gas probe calibration
The flue gas probe does not require calibration as it is already linearized in the factory.
The value on the display represents the probe temperature. Press the keys
1
and
2
(
decrease and increase temperature
) to
have this value correspond to the temperature detected by the thermometer near the probe.
In practice, if the operation is performed with the heat stove off and cold, the reading just needs to correspond with the room
temperature detected by the thermometer of reference.
See the example in the following figure.
Confirm calibration by pressing the key 7.
fig. 51