Programming setting
42
7.5.4 - HEAT STOVE WORKING
When the starting phase has ended successfully, the heat stove switches to working mode which represents the normal operating
mode. If the temperature of the heat stove is greater than 50°C, the system pump switches on.
7.5.5 - CHANGING ROOM TEMPERATURE SETTING
To change the room temperature, just select the ROOM SETTING MODIFICATION mode by pressing key 4.
Then press keys 1 and 2. The display shows the current temperature SETTING status.
N.B. The thermostat leaves the factory with the external room thermostat bridged in order to disable the internal room probe
function of the heat stove. This avoids unintentional modulations due to small environments.
If you wish to use the room probe inside the heat stove, remove the bridge on the rear pin marked “room thermostat”.
7.5.6 - USING EXTERNAL THERMOSTAT / CHRONOTHERMOSTAT
If you wish to use an external room thermostat, perform the connection on the back of the heat stove on the pin marked “room
thermostat” in terminals T1 and T2.
·
external thermostat
: on STILE 27, set a temperature of 7°C.
·
external chronothermostat
: on STILE 27, set a temperature of 7°C and disable the chrono functions from the menu 03-01.
fig. 29
fig. 30
15 : 18
21°C
LAVORO
orologio
temperatura ambiente
dialogo
potenza
P-3
SET TEMP
valore impostato
dialogo
AMBIENTE
28°C
clock
room temperature
dialogue
output
set value
dialogue
Содержание STILE 27
Страница 1: ...INSTRUCTIONS FOR INSTALLATION MAINTENANCE AND USE 00334578 05 13 rev 0 STILE 27...
Страница 59: ...Notes...