Programming setting
5 3
7.8.1 - Submenu 08 - 01 - 01
Select the pellet feeding variation value with 1 and 2. Confirm with 7.
7.8.2 - Submenu 08 - 02 - 01 chimney type
Select the flue gas intake fan speed variation value with 1 and 2. Confirm with 7.
7.8.3 - Submenu 08 - 03 database
The device has a series of default settings inside called
DATABASE
(recipes).
These settings, the number of which depends on the version of the device, are available and non-modifiable to allow, for
example, adaptation to several types of pellets and/or flue gas discharge pipes without needing to program one parameter at
a time, or depending on particular needs.
To load the recipes, just type in the correct code corresponding to the desired database, referring to the table in
ANNEX A
.
7.8.4 - Submenu 08 - 04 various settings
Allows to set a series of operational parameters.
Refer to
ANNEX A
.
7.8.5 - Submenu 08 - 05 outputs test
Select the output device to activate.
For the flue gas intake fan and heat exchanger fans it is possible to set the voltage to be applied during the test.
For the feeding screw, it is possible to pre-establish the activation time for the test.
Scroll with keys 4 - 5, confirm with keys 1 - 2.
Pressing the key 3 interrupts the test.
7.8.6 - Submenu 08 - 06 factory settings
With this function, the flue gas probe is linearized in the factory (see paragraph 7.7.1).
7.8.7 - Submenu 08 - 07 reset partial hours
Accessible only with password.
Resets the partial operating hours at zero.
fig. 49
fig. 50
CARICA
PELLET
M-8- 1-01
00
ASP-FUMI
CAMINO
M-8- 2-01
00