Technical features and dimensions
1 1
2.3 - TECHNICAL DATA
* Pressure drops for flow rate corresponding to a thermal drop of 15K.
** Values calculated based on the Law 10/91 for residential homes with a heat requirement of 30 kcal/hm³. The data is indicative.
*** NOTE: DHW production is subordinated to operation of the system pump. This cannot start up until the water temperature in the heat stove reaches 40°C. Beyond
this threshold it is necessary to consider the time required for the water temperature in the heat stove to reach a degree which allows thermal exchange through
the plate heat exchanger. A pressure drop caused by the thermal exchange is also considered. Therefore, with the heat stove at full capacity and water
temperature of 80°C, with a continuous withdrawal of 10 litres a minute, the outlet temperature from the DHW exchanger will be approximately 40°C with cold water
inlet at approximately 10°C.
The results in the table have been obtained using certified pellets based on the standards DIN 51731, DINplus and ÖNORM M 7135.
Emissions: according to UNI EN 14785
Efficiency: according to UNI EN 14785
(kW)
5,2÷20
NOMINAL OUTPUT
HEAT STOVE CAPACITY
WATER SIDE PRESSURE DROPSA (standard version)
*
MAX. WORKING PRESSURE
PELLET TANK CAPACITY
(m.w.c.)
(l)
35
0,3
(bar)
(kg)
2
60
(kW)
8÷27
THERMOCHEMICAL OUTPUT
FLUE GAS TEMPERATURE
(°C)
max. 180°C - min. 80°C
(W)
395
ELECTRIC ABSORPTION
starting
250
full capacity
(W)
FLUE GAS MASS FLOW RATE
(g/s)
10,20
CO VALUE 13%
(%)
< 0,04
TOTAL EFFICIENCY
(%)
81,48
MINIMUM DRAUGHT
(Pa)
10
85
1,65
5,62
min.
max.
PELLET CONSUMPTION
(kg/h) min.
max.
10,7
36,4
AUTONOMY
(h)
at nominal flow rate
at minimum
2.4 - SUPPLY
standard
Controlled combustion system with flue gas
temperature recovery
standard
Flue gas draught control pressure switch
standard
Dual combustion system
standard
Ceramic glass
standard
Two-way remote control
Automatic re-ignition in case of blackout (within 60 seconds)
5-speed forced ventilation
Possibility of setting heat outputs (5 levels)
Weekly programming
standard
standard
standard
standard
MAX HEATABLE VOLUME
**
(m³)
573
DHW PRODUCTION (see note)
***
(l/min.)
10
(kW)
6,8÷22
OVERALL OUTPUT