Programming setting
44
7.5.9 - THE WATER TEMPERATURE REACHES THE SET TEMPERATURE
(SET water temperature)
When the water temperature has reached the set value, even simultaneously to that described in paragraph 7.5.8, the heat
output is automatically brought to the minimum value, MODULATION condition
.
Similarly to that which occurs for the room temperature, if the STANDBY mode has been activated, STILE 27 switches off;
namely is placed in STANDBY, with a 5 minute delay and after having exceeded the value (T
SET
+ 2°C).
(only if the Wieland plug of the external TA has a bridge on T1 and T2).
7.5.10 - RESTARTING AFTER EXTINCTION HAVING REACHED SET ROOM AND/OR WATER
TEMPERATURE
After the STANDBY extinction, STILE 27 places itself in cooling condition bringing the flue gas intake fan to a maximum. See
figure 21.
The restarting conditions are:
Air:
T
room <
(T
SET
- 2°C) and simultaneously Tflue gas < 50°C
Water:
T
water <
(T
SET
- 2°C) and simultaneously Tflue gas < 50°C
fig. 33
fig. 34
dialogo
orologio
temperatura ambiente
16 : 40
LAVORO
MODULA
27°C 55°C
temperatura acqua
dialogo
orologio
temperatura ambiente
22 : 25
ATTESA
RAFFRED-
24°C 56°C
temperatura acqua
dialogue
clock
water temperature
room temperature
dialogue
clock
water temperature
room temperature