background image

Installation instructions

2 1

General warnings

The electrical safety of the system is guaranteed only when it

has been properly connected to an efficient earthing system

carried out as intended by safety standards in force: pipes of

the gas, water and heating systems are absolutely unsuitable

as earthing electrodes.

It is necessary to verify this fundamental safety requirement. If

in doubt, have the electric system carefully checked by

professionally qualified personnel as the manufacturer of the

heat stove is not liable for damage caused by failure to provide

an earthing system.

Have professionally qualified personnel check that the electric

system is adequate for the maximum power absorbed by the

system. Make sure in particular that the cross-section of the

cables is suitable for the power absorbed by the loads.

Adapters, multiple sockets and/or extension cords cannot be

used to power the pumps or other loads from the electric mains.

Use of any type of component using electric energy requires

the observance of some fundamental rules, such as:

• do not touch the appliance with wet and/or moist parts of

the body and/or in bare feet;

• do not pull the electric cables;

• do not leave the appliance exposed to atmospheric agents

(rain, sun, etc.) unless expressly designed;

• do not allow children or unskilled persons to use the

appliance.

230V electric power supply connection

The general electrical connections are illustrated on page 22

and 23.

Installation of the electrical accessories of the heat stove

requires connection to a 230 V - 50 Hz electric mains: This

connection must performed up to standard as intended by

current IEC regulations.

Danger!

Only a qualified technician may perform the

electrical installation.

Before performing connections or any type

of operation on electrical parts, always

disconnect electrical power and make sure

that it cannot be reconnected accidentally.

Remember that a bipolar switch must be

installed on the heat stove power line with over

3 mm between contacts, easy to access, making

maintenance quick and safe.

The power cable must be replaced by authorised technical

personnel. Failure to comply with the above can jeopardise

the safety of the appliance.

ELECTRIC

CONNECTIONS

4

Содержание STILE 27

Страница 1: ...INSTRUCTIONS FOR INSTALLATION MAINTENANCE AND USE 00334578 05 13 rev 0 STILE 27...

Страница 2: ...29 7 1 Using the product 29 7 2 Remote control 30 7 3 Function of buttons 32 7 4 Menu 33 7 4 1 User menu 33 7 4 2 Menu 01 set clock 35 7 4 3 Menu 02 set chrono 35 7 4 4 Menu 03 choose language 39 7 4...

Страница 3: ...rm 50 7 8 Operational mode technical menu 51 7 8 1 Submenu 08 01 01 53 7 8 2 Submenu 08 02 01 chimney type 53 7 8 3 Submenu 08 03 database 53 7 8 4 Submenu 08 04 various settings 53 7 8 5 Submenu 08 0...

Страница 4: ...thereafter 1 4 INFORMATION FOR USER The user must be instructed concerning the use and operation of his heating system in particular Deliver these instructions to the user as well as other documents...

Страница 5: ...which the manufacturer cannot be held responsible Modifying parts connected to appliance Do not modify the following parts the heat stove the air water and electricity lines the flue gas pipe safety...

Страница 6: ...isconnect the appliance from the energy mains by acting on the switch of the system or by unplugging it Do not obstruct the terminals of the intake exhaust ducts In case of failure and or malfunctioni...

Страница 7: ...owder painted sheet steel casing 2 TECHNICAL FEATURES AND DIMENSIONS 1 Emergency console 2 Front cleaning door equipped with ceramic glass 3 Bottom cleaning cover 4 Main switch with plug 5 Remote cont...

Страница 8: ...nsion vessel preloaded at 1 bar supplied 4 System filling tap not supplied 5 System shut off valves not supplied 6 Main pump supplied 7 System drain tap not supplied Indicative hydraulic diagram fig 2...

Страница 9: ...water production unit T1 CH flow R 3 4 T2 CH return R 3 4 T3 Chimney connection 100 T4 Air intake connection 80 T5 Safety valve discharge connection R 3 4 T6 Domestic hot water outlet connection T7 Do...

Страница 10: ...ling tap not supplied 5 System shut off valves not supplied 6 Main pump supplied 7 DHW system shut off valve not supplied 8 Domestic cold water inlet filter not supplied 9 Differential flow switch sup...

Страница 11: ...n obtained using certified pellets based on the standards DIN 51731 DINplus and NORM M 7135 Emissions according to UNI EN 14785 Efficiency according to UNI EN 14785 kW 5 2 20 NOMINAL OUTPUT HEAT STOVE...

Страница 12: ...he STILE 27 heat stove is that of burning natural fuel pellets obtained in an environmentally friendly way from wood industry waste sawdust powders The sawdust and powders coming from wood processing...

Страница 13: ...with untreated wood sawdust without other materials added It is absolutely forbidden to use any solid or liquid fuel other than pellets to feed STILE 27 For best operation of STILE 27 it is recommende...

Страница 14: ...sonnel a Thoroughly wash all the piping of the system to remove any residue or impurities which could jeopardise proper operation of the heat stove b Check that the chimney flue has an appropriate dra...

Страница 15: ...ndard UNI 10847 of March 2000 Single flue systems for generators fed by solid and liquid fuels Maintenance and control Guidelines and procedures FIELD OF APPLICATION systems fed with solid and liquid...

Страница 16: ...e obstructed The correct air influx can also be guaranteed by using openings towards an adjacent room as long as that room is provided with direct ventilation and it has no fire risks such as depots g...

Страница 17: ...lue gas chimney must be made properly to favour the normal flow of flue gas from the combustion chamber towards the outside in the case of a power outage Remember that the elimination of excess heat i...

Страница 18: ...ys provide an inspection plug which allows you to perform efficient and periodical cleaning as well as draining any condensation formed The chimney must be strictly wind and rain proof Appropriately i...

Страница 19: ...ion of combustion products and to the corrosive action of condensation which could be formed Predominately vertical with deviations no greater than 45 It is recommended to provide a solid material and...

Страница 20: ...e connections This operation must be performed carefully respecting the following phases open the radiator air release valves open the filling tap gradually making sure that the automatic air release...

Страница 21: ...the observance of some fundamental rules such as do not touch the appliance with wet and or moist parts of the body and or in bare feet do not pull the electric cables do not leave the appliance expos...

Страница 22: ...lu marrone marrone azzurro rosso bianco Termost ambiente verde marrone FILTRO DI RETE 230V posizionata sul posteriore della caldaia T A esterno PI ALM Trasduttore di pressione OUT giallo marrone verde...

Страница 23: ...o Termostato ambiente T1 T2 NOTA in caso di montaggio del TERMOSTATO AMBIENTE togliere il ponte sulla presa Wieland vedere figura sopra C NA PRACTICAL WIRING DIAGRAM with DHW production kit fig 11 pow...

Страница 24: ...ation of his heating system in particular Deliver these instructions to the user as well as other documents concerning the appliance inserted in the envelope inside the packaging The user must keep th...

Страница 25: ...s and their extent are determined by a specialist based on the status of the appliance ascertained through inspection Inspection and maintenance jobs must be performed in the order shown on page 26 In...

Страница 26: ...ntegrity of the flue gas exhaust pipe and or device If work or maintenance is performed on the structures near the flue gas pipes and or flue gas exhaust devices and their accessories switch the appli...

Страница 27: ...moisture causing possible malfunctioning the next time it is lit We also recommend thoroughly cleaning both the chimney and the flue gas fitting to avoid the risk of a fire Put all the components back...

Страница 28: ...d problems which could arise while using STILE 27 1 Make sure power is present and that the power cable is connected 2 Contact technical assistance 3 Place the switch at ON Remedy 1 Contact technical...

Страница 29: ...the room must be well ventilated during this phase Remember that the appliance must always operate with the combustion chamber door closed Though the surface temperatures which our appliance reaches a...

Страница 30: ...ake on different meanings according to the position on the screen Example with STILE 27 off 7 2 REMOTE CONTROL The following figure shows the arrangement of the messages during programming or operatin...

Страница 31: ...CALDAIA SENSORE TEMPERATURA AMBIENTE SET POTENZA Scorri men The figure below describes the keys of the remote control and the functions linked to them The set operations are viewed on the display fig...

Страница 32: ...seconds it switches STILE 27 on or off if it is off or on respectively ON OFF unblock 3 BLOCK Unblocks STILE 27 and switches it off MENU PROGRAMMING Accesses the higher menu level modifications perfo...

Страница 33: ...available for the user level 1 level 2 level 3 level 4 value 01 clock setting day week 01 day time 02 hours minute 03 minutes day month 04 day month 05 month year 06 year 02 chrono setting 01 enable...

Страница 34: ...nday prog 4 on off 01 chrono week end 02 start 1 03 stop 1 04 start 2 05 stop 2 11 start prog 2 12 stop prog 2 13 Monday prog 2 14 Tuesday prog 2 15 Wednesdayprog2 16 Thursday prog 2 17 Friday prog 2...

Страница 35: ...ve status 7 4 2 MENU 01 clock setting Sets the current time and date The board is provided with a lithium battery which provides the internal clock with over 3 5 years of autonomy 7 4 3 MENU 02 chrono...

Страница 36: ...ng time periods delimited by the times set according to the following table where the OFF setting tells the clock to ignore the control START 1 STOP 1 START 2 STOP 2 selection meaning possible values...

Страница 37: ...PROG 1 selection meaning possible values activation time deactivation time time OFF time OFF on off on off 02 03 02 02 03 03 02 03 04 02 03 05 menu level PROGRAM 1 WEDNESDAYPROG1 on off 02 03 06 THURS...

Страница 38: ...3 on off 02 03 27 SUNDAY PROG 3 on off 02 03 28 START PROG 4 STOP PROG 4 MONDAY PROG 4 TUESDAY PROG 4 selection meaning possible values activation time deactivation time time OFF time OFF on off on o...

Страница 39: ...5 MENU 04 standby mode Activates STANDBY mode which leads the heat stove to switch off after the water temperature has reached the set point beyond the time determined by the triggering of the externa...

Страница 40: ...rete 7 4 8 MENU 07 heat stove status Displays the instant status of the heat stove providing the status of the various devices connected to it Various pages are available displayed one after another...

Страница 41: ...n in the following figure 7 5 2 STARTING PHASE STILE 27 carries out the starting phases in sequence according to the modes defined by the parameters which manage their levels and times 7 5 3 FAILED IG...

Страница 42: ...ernal room probe function of the heat stove This avoids unintentional modulations due to small environments If you wish to use the room probe inside the heat stove remove the bridge on the rear pin ma...

Страница 43: ...ed the set value the heat output is automatically brought to the minimum value MODULATION condition N B This is only possible if the bridge of the room thermostat behind the heat stove has been remove...

Страница 44: ...y if the Wieland plug of the external TA has a bridge on T1 and T2 7 5 10 RESTARTING AFTER EXTINCTION HAVING REACHED SET ROOM AND OR WATER TEMPERATURE After the STANDBY extinction STILE 27 places itse...

Страница 45: ...crew stops immediately and the flue gas extractor switches to high speed The FINAL CLEANING phase is performed The flue gas extractor is disabled after the flue gas temperature has dropped below 50 C...

Страница 46: ...t stove until the flue gas temperature has dropped below 50 C and 5 minutes have passed fig 37 fig 38 dialogo orologio temperatura ambiente 21 10 22 C SPENTO potenza P 1 dialogo orologio temperatura a...

Страница 47: ...SING If the mains voltage is missing for over 60 seconds when it is restored STILE 27 will place itself in the FINAL CLEANING status and remains in standby until the flue gas temperature has dropped t...

Страница 48: ...FAIL AL 7 General safety thermostat ALARM FAN FAIL AL 4 Flue gas fan failure BLACK OUT AL 1 Blackout ALARM PRES AL 11 Water pressure beyondallowedvalues H2O PROBE ALARM AL 9 Water probe failure ALARM...

Страница 49: ...triggers The extinction procedure is activated immediately 7 7 5 SCREW SAFETY PRESSURE SWITCH ALARM Should the pressure switch depression security thermostat detect a pressure beyond the standard it t...

Страница 50: ...usly via the terminal AL1 in CN4 allows the controller to acquire this status change The message ALARM SAFETY FAIL appears and the system is stopped 7 7 7 FLUE GAS INTAKE FAN FAULT ALARM In the event...

Страница 51: ...ings level 2 level 3 level 4 value 01 pellet type set 02 chimney type see database 03 database 01 re ignitionblock 02 min intake off value 03 ignition preloading value 04 flame standby value 05 preloa...

Страница 52: ...memories 01 igniter test 02 screw test value 03 flue gas test value 04 pump test value 05 fan 2 test value value 05 outputs test 06 fan 3 test value password password 08 reset alarms total hours parti...

Страница 53: ...the correct code corresponding to the desired database referring to the table in ANNEX A 7 8 4 Submenu 08 04 various settings Allows to set a series of operational parameters Refer to ANNEX A 7 8 5 Su...

Страница 54: ...lue gas probe calibration The flue gas probe does not require calibration as it is already linearized in the factory The value on the display represents the probe temperature Press the keys 1 and 2 de...

Страница 55: ...13 M 8 6 13 Minimum flow gas temperature to consider heat stove on C 40 180 Pr14 M 8 6 14 Flue gas temperature to switch to ECO MODULA mode C 110 250 Pr15 M 8 6 15 Flue gas temperature threshold to sw...

Страница 56: ...meter Menu level Description Pr36 M 8 4 01 Re ignition block Unit of measurement Admittedvalue range minute 0 10 Pr39 M 8 4 02 Flew gas intake fan switch off time minutes 0 20 Pr40 M 8 4 03 Preloading...

Страница 57: ...RICA PELLET PRECARICA ACCENSIONE ATTESA CARICA accensione caldaia temperatura fumi comando pompa comando asp fumi comando coclea candeletta stato impianto Pr33 temperatura pompa accesa temperatura acq...

Страница 58: ...on off on off on off on LAVORO T Pr12 T Pr03 da Pr23 a Pr27 Pr22 da Pr18 a Pr22 da Pr18 a Pr22 T T da Pr06 a Pr10 da Pr06 a Pr10 bassa fig 54 WORKING CLEANING BRAZIER WORKING Boiler working phase low...

Страница 59: ...Notes...

Страница 60: ...ww unical eu info unical ag com Unical will not be held responsible for possible inaccuracies if due to transcription or printing errors It also reserves the right to modify its products as deemed nec...

Отзывы: