SECTION 9
TROUBLESHOOTING
82
9
9
35
36
38
45
EI:INV. OVERVOLT
EI:DC-DC LOW VOLT
EI:DC-DC OVERVOLT
EI:BRAKE OVERTIME
Defective circuit in the
power supply unit.
Turn the power on again after the
pump stops. The power supply unit
must be repaired if the problem
occurs again.
10
39
EI:DEW ERROR
Internal condensation
Check that the ambient temperature
and humidity around the pump and
the temperature of cooling water are
within the specified range.
Check there are no solids piled up in
the water valve.
Drive again after leave it for a while.
4.1
5.3
11
43
EI:PARAM ERROR
Defective circuit in the
power supply unit.
Turn the power on again after the
pump stops. The pump must be
repaired if the problem occurs again.
12
44
66
67
EI:CPU ERROR
MB:DSP ERROR
MB:DSP OVERFLOW
Abnormal operation of
circuit in the power
supply unit.
Check that the ambient temperature
around the pump is within the
specified range.
Check that the temperature and flow
rate of the cooling water are within
the specified ranges.
Check that equipment causing noise
is not used around the pump and
power cable.
4.1
4.3
5.2
5.3
13
48
EI:ACCEL OVERTIME
Rotation speed does
not increase at start-
up.
Check that the outlet and inlet
pressures are not too high.
Check for leakage.
Check that too much purge gas is not
flowing.
6.2
14
49
TMP:CAN NOT START
Pump does not rotate.
Adhesion of reaction products or
damage to the protective bearing is
the possible cause. Remove the
pump from the unit and check that the
rotor blades rotate smoothly at the
inlet. An overhaul is required if blades
do not rotate smoothly.
15
51
52
53
54
55
56
57
58
59
60
MB:VIBRATION2 X1
MB:VIBRATION2 Y1
MB:VIBRATION2 X2
MB:VIBRATION2 Y2
MB:VIBRATION2 Z
MB:VIBRATION1 X1
MB:VIBRATION1 Y1
MB:VIBRATION1 X2
MB:VIBRATION1 Y2
MB:VIBRATION1 Z
Strong external shock
or vibrations.
If the shock or vibrations are transient
re-acceleration is possible. If the
shock or vibrations occur frequently,
stop the pump and remove the source
of the shock or vibrations ; or re-
examine the pump mounting method.
16
61
62
63
64
65
MB:SENSOR ERR. X1
MB:SENSOR ERR. Y1
MB:SENSOR ERR. X2
MB:SENSOR ERR. Y2
MB:SENSOR ERR. Z
The rotor does not
move due to adhering
matter or a damaged
touch-down bearing.
Remove the pump and check that the
rotor rotates smoothly. The pump
requires an overhaul if the rotor does
not rotate or the resistance to rotation
is large.
17
68
69
MB:BALANCE AXIS1
MB:BALANCE AXIS2
Rotor inside the pump
is out of balance.
Adhesion of reaction products is a
possibility. An overhaul is required.
Alarm
code
Alarm name
Possible cause
Remedy
Sec-
tion
Содержание UTM1200 Series
Страница 2: ...This page is intentionally left blank...
Страница 10: ...viii Location of Label...
Страница 26: ...12 2 2 4 External I F Panel This page is intentionally left blank...
Страница 27: ...3 3CONSTRUCTION AND PRINCIPLE 3 1 Pump Construction 3 2 Principle of Turbo Molecular Pumping 3 3 Controller...
Страница 32: ...18 3 3 3 Controller This page is intentionally left blank...
Страница 38: ...24 4 4 4 Standards Fulfilled This page is intentionally left blank...
Страница 54: ...40 5 5 5 Notes on Transportation This page is intentionally left blank...
Страница 78: ...64 6 6 8 Communication Specifications This page is intentionally left blank...
Страница 79: ...7 7GAS PURGE...
Страница 88: ...74 8 8 6 Turbo Molecular Pump Return Request This page is intentionally left blank...
Страница 101: ...10 10WARRANTY CLAUSES...
Страница 104: ...90 10 This page is intentionally left blank...
Страница 106: ...Index Index 2 This page is intentionally left blank...