5.5 Protection feature
Protection feature to show for table 3 is incorporated in a protection feature
motor driver circuit.
When even one protection that showed in table 3 works, it is output as an
alarm signal by an outside interface connector.
Table 3 Protection feature
Protection
item
Contents
1 Overheat
protection
Be motor stopping when do rise in heat to
80
℃
±10%
2
Power supply over voltage
protection
Be more than AC144V or AC288V, and a
motor stops
3 Anomaly of a Hall element IC
Motor stops unless signal from a Hall
element IC are detected.
4 System error
Motor stops in computer anomaly
5 Over speed protection
When rotating speed goes over 4200min
-1
, be
motor stopping
6 Over current protection
Be motor stopping when go over torque
0.96N
・
m
7 Over current electric fuse
AC250V 10A
8
Magnet coupling step out
detection
Be step out detection when become less
than torque 0.13N
・
m
Operation mode 3
A protection feature is reset by exclusion of an error cause and electric
source off more than 10 second.
But 3 4 7 of protection item becomes repair required.