Section 1 C30VR Compressor Description
ULVAC CRYOGENICS INCORPORATED
1-7
Table 1-6
Electromagnetic environment resistance characteristics
Item Specification
Insulation resistance (Between power
supply, Input-output and Ground)
5M
Ω
and more / 1 min.
(500V megohmmeter)
Dielectric withstanding voltage
(Between
power line and ground)
1500V / 1 min.
Noise immunity (Power line)
(*1)
±1500V
Noise immunity (Input-output line)
(*1)
±500V
(*1)By fast transient/burst method.
Test duration : 1 min.
1.7 Component descriptions
This section describes components which need adjustments and/or verifications during
operation and maintenance.
Compressor front view is shown in Figure 1-6 and rear view in Figure 1-7 (both
C30MVR).
Figure 1-6
Compressor front view
⑤
CASTERS
④
HELIUM FILL FITTING
(inside the panel
)
⑥
ALARM STATUS TABLE
③
COM
PORT
:MONITORING
⑦
STATUS DISPLAY and
RESET BUTTON
①
ELAPSED TIME METER
②
HIGH PRESSURE
HELIUM GAS
PRESSURE GAUGE
FRONT PANEL
Содержание C30MVER
Страница 2: ......
Страница 8: ...F 6 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank ...
Страница 16: ...S 4 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank ...
Страница 18: ...IW 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank ...
Страница 32: ...C30VR Compressor Instruction Manual 1 14 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank ...
Страница 108: ...CS 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank ...
Страница 110: ...Revision History R 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank ...