UltraVision Security, Inc. • Salem, New Hampshire 03079 USA • Tel 866.374.9732 • 603.685.0303 • Fax 603.898.1840
www.UltraVisionSecurity.com • [email protected]
Rev 031109
4
In very cold regions or where clay soils may prohibit drainage of water from the CMD installation,
then holes should be drilled another two feet into the soil and then filled with pea gravel to permit
better drainage. This type of installation will also provide better protection from freeze-thaw cycles
over time.
Server-24
The
CMD Server
box provides the power and Ethernet connections to the CMD sensors. Up to 24
sensors can be connected to and powered from the basic server (shown below). Other servers are
available with additional capacity and dry switches. Dry contact connections are provided for each
sensor so that alarms can be turned on and/or CCTV camera presets can be utilized. The server also
provides the gateway to the security network - and the Internet. It is lockable and made of steel,
designed for wall mounted applications.
The server logs all alarms and monitors the sensor ‘heartbeat’ to insure each one is working. The
internet connection allows users with the proper password to access the information from any
location.
The following diagram shows the primary connections that can be made to the Server.
AC Power
Direct Connections (4)
Daisy Chain Connections (2)
Dry Switch
Connections (24)
Internet Connection