UltraVision Security, Inc. • Salem, New Hampshire 03079 USA • Tel 866.374.9732 • 603.685.0303 • Fax 603.898.1840
www.UltraVisionSecurity.com • [email protected]
Rev 031109
23
Contact Closure Detail
•
Motion
– motion detected by an UltraSensor that meets the alarm threshold criteria defined
on the Configuration page will be indicated by a red icon on the Monitor Screen and recorded
in the Log. It will also cause the chosen contact to open or close, as selected, sending a signal
to associated systems (CCTV, access control, etc.).
•
Warning
– is an indication of motion within the full extent of the UltraSensor detection range
but greater than the alarm range parameters set on the Configuration page. Icon will become
yellow. Setting “warning” to open or close will cause the chosen contact to activate associated
systems. Recommended setting is ignore except in high security applications where
recognition of any motion within range of the UltraSensor is desirable.
•
No-Motion
– an absence of motion within the full range of an UltraSensor will be indicated
by a green icon on the Monitor Screen.
No-motion
will cause the chosen contact to open or
close, as selected, sending a signal to an associated systems (CCTV, access control, etc.). If
Motion
is set to open, set “No-motion” to closed. If
Motion
is set to closed, set “No-motion”
to open.
•
Noise
– the occurrence of RF interference with performance of an UltraSensor will be
indicated by a blue icon on the Monitor Screen and recorded in Log. Setting
noise
to either
open or closed will cause the activation of an associated system to create another level of
awareness.
•
Heartbeat
– UltraSensor communicates with the Server twice per second and upon initial
power up “heartbeat” is displayed on the User Interface and recorded in the System log.
Succeeding “heartbeats” are not logged nor displayed. If a Sensor loses communication with
the System (cut cable, power loss, Sensor malfunction, etc.), a visual indication will be
generated on the Monitor Screen (orange icon with “X”) and recorded in the Log. Setting
“heartbeat” to open or close will cause an activation of a contact upon initial power up only.
Heartbeat
is the opposite of “power.” Recommended setting for
heartbeat
is ignore.
•
Power
– an absence of individual Sensor power will generate a visual indication on the
Monitor screen (orange icon with “X”) and be recorded in the Log. Setting “power” to close
or open will cause an activation of the contact upon power loss only.
The choice of open or closed will be based upon the required input status of the associated system.
Individual contacts
may
be programmed for multiple non-conflicting functions. For example when
integrating with a CCTV system, Contact #1 can be set to open on
No-motion
, close on
Motion
, and
close on
Warning
to activate a camera to record
any
motion from a given UltraSensor. Operational
conditions like
Power
and
Heartbeat
would normally not call for camera activation and should be
linked to other contacts to create operator or monitor awareness.