UltraVision Security, Inc. • Salem, New Hampshire 03079 USA • Tel 866.374.9732 • 603.685.0303 • Fax 603.898.1840
www.UltraVisionSecurity.com • [email protected]
Rev 031109
9
Server to
CB-06
SERVER
and system
power
CB-06 to
CB-06
CB-06 to
CB-06
CB-06 to
CB-06
UltraSensor™
Security system using
daisy-chain connection of
concentrator boxes
Laptop
CB-06
Network
or Internet
NOTES:
Each UltraSensor (CMD) has a separate Ethernet cable that connects it to the CB-06 Concentrator Box.
Power is supplied through the Ethernet cable (POE).
Each Concentrator Box (CB-06) has a separate Ethernet cable AND a power cable (both parallel cables
shown by dashed line) that connects it to another CB-06 Box and finally to the SERVER and Power
The SERVER also has a dry switch output (twisted pair) for each CMD sensor.
A maximum of 4 CB-06 Boxes can be in a single daisy-chain from the SERVE .
Maximum cumulative cable distance from the SERVER to any CMD sensor is 1,200 feet (390m).
CB-06
CB-06
CB-06
CB-06 to CMD
Max distance 67m
CB-06 to CMD
Max distance 67m
CMDs
Connect 0 to 6
CMD sensors
Connect 0 to 6
CMD sensors
Connect 0 to 6
CMD sensors
Connect 1 to 6
CMD sensors
Dry switch output
for each CMD
CMDs
CMDs
CMDs
Содержание UltraSensor CMD-2
Страница 31: ...Rev 031109 31...
Страница 36: ...Rev 031109 36 Dry contact switch specifications for Server 8...
Страница 37: ...Rev 031109 37 Dry contact switch specifications for Server 24...