background image

 

 

 

 

 Rev 031109 
 

42

 

Added the 

Archived Logs

 button to the 

View Audit Log

 page to allow administrators to 

view the list of Audit Log archive files currently stored on the server.  The new 

Audit 

Log Archive 

page also allows administrators to export a CSV file containing all archived 

audit records for a given day.  

 

 

Modified the 

View Audit Log

 and 

View Event Log

 displays to limit the number of rows 

displayed in the GUI table and exported to a CSV file.  This prevents users from 
accidentally trying to display more rows than the database, web server and browser are 
capable of handling.  

 

Server Changes  

 
The following specific changes were made to the server functionality and configuration 
mechanisms:  

 

Fixed a bug that was preventing switch actions based on the 

POWER

 event from 

triggering properly.  

 

 

Added support for the 

UltraSensor Switch API

 that allows client applications to receive 

switch state changes as defined on the 

Configure Switches

 administrator page.  Client 

applications using this API must specify a valid 

Switch ID

 (e.g., location) and 

Access 

Code

 as defined on the 

Configure Switches

 page in order to start receiving state changes 

as events are processed by the server.  

 

 

Added support for the 

UltraSensor Monitor API

 that allows client applications to 

monitor server activity, including server property changes, target data and event data. 
Client applications using this API must specify a valid 

Monitor ID 

and 

Access Code

 as 

defined on the new 

Configure Monitors

 page in order to access the server. 

 

 

Fixed a problem with the maintenance task that prevented it from properly archiving and 
pruning the Audit/Event log on some systems.  Event records are now automatically 
deleted from the database when they are older than the number of days specified by the 

Online Event Retention

 property on the 

Configure System

 page. The 

Online Event 

Retention

 property determines how far back in time Operators and Administrators can 

view Event Log or Audit Log records using the 

View Event Log

 and 

View Audit Log

 

pages.  

 

 

The Audit Log is now archived to individual CSV files on a daily basis in the 

c:\uvss\archive 

directory on the server.  The daily files make it easier for administrators 

to find past events for a given time period.  Furthermore, the format of the archive files is 
now the same as that used when exporting the Audit Log from the GUI, making it easier 
to post-process the CSV files. Archive files are automatically removed from the file 
system when they are older than the number of days specified by the 

Archive Log 

Retention

 property on the 

Configure System 

page. 

 
 

Содержание UltraSensor CMD-2

Страница 1: ...Detail 23 Monitor Screen 23 View Log File 25 Configure Alarm Mass Threshold Sensitivity 26 Logout 26 Software Updates 26 Sensor Specifications 27 Integrating the CMD Server 24 with your network 28 Ch...

Страница 2: ...he only limitation is that the sensor cannot be covered with sheet metal or a dense metal mesh material The radial range of the sensor is 22 to 25 feet 6 5 to 8 meters and it covers an elliptical patt...

Страница 3: ...45cm by about eighteen inches 45 cm deep A four inch 10 cm layer of sand is placed in the hole and the sensor is placed on top of the sand The sensor is then covered with sand about one inch 2 5 cm d...

Страница 4: ...an be connected to and powered from the basic server shown below Other servers are available with additional capacity and dry switches Dry contact connections are provided for each sensor so that alar...

Страница 5: ...ty com Rev 031109 5 Server 8 The CMD Server 8 is a laptop computer system that connects up to 8 sensors to collect and log data This version of the Server is more compact and appropriate for smaller s...

Страница 6: ...raVision Security Inc Salem New Hampshire 03079 USA Tel 866 374 9732 603 685 0303 Fax 603 898 1840 www UltraVisionSecurity com info UltravisionSecurity com Rev 031109 6 USB connection Ethernet connect...

Страница 7: ...cable The cable should be carefully unrolled during installation Kinks in the wire can cause breaks and internal signal reflections which will degrade the signal from the sensor The Ethernet cable ma...

Страница 8: ...er is supplied through the Ethernet cable Each Concentrator Box CB 06 has a separate Ethernet cable that connects it directly to the SERVER and power all through the Ethernet cable POE The SERVER also...

Страница 9: ...hrough the Ethernet cable POE Each Concentrator Box CB 06 has a separate Ethernet cable AND a power cable both parallel cables shown by dashed line that connects it to another CB 06 Box and finally to...

Страница 10: ...p Server can have up to two hubs connected and a maximum of 8 sensors all direct connected 2 CMD Server 24 can deploy 24 sensors 3 CMD Server 48 can deploy 48 sensors 4 Servers can be customized depen...

Страница 11: ...ke note of wire colors and twisted pairs Note Your cable will have its own color combinations What is important is that it is wired the same on both ends and twisted pairs stay together 3 The backshel...

Страница 12: ...3 3 Blue Shield 4 4 Shield 10 Squeeze tabs and return red section into black 11 Screw backshell onto connector It may be easier to temporarily connect to a CMD box while installing the backshell 12 Ti...

Страница 13: ...UltraVision Security Inc Salem New Hampshire 03079 USA Tel 866 374 9732 603 685 0303 Fax 603 898 1840 www UltraVisionSecurity com info UltravisionSecurity com Rev 031109 13...

Страница 14: ...any combination of UltraSensors may be mixed on either Concentrator Box Up to six Sensors are managed by one Concentrator Box To return to the Windows desktop while the UltraSensor software is runnin...

Страница 15: ...rnet Explorer icon on the desktop You may see a Certificate Error page pop up If that happens simply click Continue to this website 3 On the Log in screen User is Admin and the password is generic11 T...

Страница 16: ...x 603 898 1840 www UltraVisionSecurity com info UltravisionSecurity com Rev 031109 16 Create Edit Users 1 Upon successful log in the Option Menu will be displayed Select Setup Users 2 This page is use...

Страница 17: ...6 Configuration Manager will confirm that User has been successfully added 7 Click Continue to return to Create User screen Continue to add Users or if finished select another screen from the menu on...

Страница 18: ...ng drop down box select timed settings for this sensor or always on as default a Use DEFAULT Settings AT ALL TIMES ignore schedule i For Scanning Status Select Enabled ii Enter Alarm Range Threshold M...

Страница 19: ...nd the Stop Hour and Minute Setting can cross midnight i e 11 PM Monday evening Start and 3 AM Tuesday morning Stop vi Enter the Alternate Scanning status Alternate Alarm Range Threshold and Alternate...

Страница 20: ...tandard US feet or Metric meters 6 Select Alarm Logging Options twice per second or once per incident a Choosing once per incident will display and log sensor activity upon state change only After act...

Страница 21: ...hould appear Click Config Set Map scale in the upper tool bar Enter a distance ft for configuring the map The distance will show on the map image Move the distance boxes until the distance matches a k...

Страница 22: ...to add a new switching device Enter the location access code and number of settings Save 5 Edit Device is used to change the access code or number of contacts 6 Use the drop down boxes to configure e...

Страница 23: ...be indicated by a blue icon on the Monitor Screen and recorded in Log Setting noise to either open or closed will cause the activation of an associated system to create another level of awareness Hea...

Страница 24: ...ntation of the facility with Sensors in approximate locations will be displayed 2 The circle surrounding each Sensor displays the approximate total detection area of each Sensor Colored circle icons i...

Страница 25: ...rning events on a yellow background alarm events on a red background and heartbeats on a green background 4 Alarms may be Archived or Dismissed Only Administrative Level users may Archive or Dismiss e...

Страница 26: ...different for each sensor This is normal as each sensor might be buried under different materials or at different depths 5 Subtract 10 from the lowest Mass reading for each sensor and enter this numb...

Страница 27: ...x to twelve inches 15 30 cm 4 Transmitter Frequency Range 200 to 600 MHz 5 POE power and communications Standard IP compatibility 6 Power user supplied 240 120 VAC to the network hub POE is 48 VDC fro...

Страница 28: ...n result in a non functioning product that must be reset by UltraVision s Support personnel For this procedure you will need a router configured with a subnet of 10 10 0 0 and a subnet mask of 255 255...

Страница 29: ...ly two ways that this can be done The easiest but less secure approach is to setup the router that communicates with your ISP Internet Service Provider to use Port Forwarding of all HTTPS services so...

Страница 30: ...gs on the left column if they are not already displayed in the center column Scroll down to use static IP address and enter your network address parameters The Server 8 is preconfigured with an IP 10...

Страница 31: ...Rev 031109 31...

Страница 32: ...operation the application resides in the Windows system tray automatically changing the switch settings as directed by the associated UltraVision Sensor Server Users can use the application GUI to mon...

Страница 33: ...complete the installation steps Running the Application When initialized the UltraVision Remote Switch Device application searches for all Measurement Computing switch devices connected to the PC via...

Страница 34: ...o open the application s Graphical User Interface GUI The GUI allows you to z Monitor and or alter the current state of each switch z Modify the server configuration information z Monitor the applicat...

Страница 35: ...plication is easily removed from the system using the following procedure z If the application is currently running double click on the icon in the system tray to open the application GUI and press Ex...

Страница 36: ...Rev 031109 36 Dry contact switch specifications for Server 8...

Страница 37: ...Rev 031109 37 Dry contact switch specifications for Server 24...

Страница 38: ...mand window will flash on the display Answer OK to any Internet Explorer error messages that you received Icons should return to appropriate colors but sensors may take up to 3 minutes to start respon...

Страница 39: ...ses to use for setting it back as a Server IP Address 10 10 101 254 Subnet Mask 255 255 255 0 Default Gateway 10 10 101 253 DNS Server 10 10 101 253 Alternate DNS is blank Select Obtain IP address aut...

Страница 40: ...isplay all services in a table To correct the switch bank issue optional you don t need to use a remote switch bank A Select Add custom service B In the NAME field type SwitchBank without quotation ma...

Страница 41: ...r to better filter false motion alarms Each of these changes are discussed in more detail below Graphical User Interface GUI Changes The following specific changes were made to the web based Guard and...

Страница 42: ...port for the UltraSensor Monitor API that allows client applications to monitor server activity including server property changes target data and event data Client applications using this API must spe...

Страница 43: ...alarms from being generated unless two or more consecutive motion events occur with a decreasing range i e target moving towards the sensor For example suppose MOTION_COUNT_FILTER is specified as 2 a...

Страница 44: ...hnical Support Email techsupport ultravisionsecurity com Contact information UltraVision Security Systems Inc 16 Northwestern Drive Salem NH 03079 USA www UltraVisionSecurity com info UltraVisionSecur...

Отзывы: