Integrating the CMD-Server 8 with your network 

 

The CMD Server 8 communicates via a Netgear FVS114 router. Using a web browser like 
Microsoft’s Internet Explorer and entering an IP address will allow you to view and control the 
server 8 as though you were physically at its keyboard. The IP address of the Server-8 is preset 
to a value of 10.10.0.10 at manufacturing time. However, this can be changed to another value if 
the preset address is not compatible with your existing network. If there is no existing network, 
the user must purchase a router and configure it to be compatible with the CMD Server-8’s 
preset IP address, or configure the CMD Server-8 to be compatible with the router if a different 
set of IP addresses is desired. 
 

Changing the CMD Server-8 IP address 

 
Warning: Changing parameters other than those described in this document can result in a non-
functioning product. 
 
On the CMD Server-8 laptop, open a web browser and type 

http://10.10.101.253

. You should 

receive a login window like the one shown on the next page. Enter the username “admin” and 
password “password” (typed without quotation marks). Select “Basic Settings” on the left 
column if they are not already displayed in the center column. Scroll down to “use static IP 
address” and enter your network address parameters. (The Server-8 is preconfigured with an 
IP=10.10.0.10, Mask=255.255.255.0, GW=10.10.0.1 and DNS Primary=10.10.0.1) When 
finished, select 

Logout 

at the bottom of the left column. Connect the CMD Server-8 Network 

connector to your network. At another computer on this same network, open a web browser and 
type the UVSS default 

https://10.10.0.10

 or the new IP that was previously entered. The Server-8 

display should now be visible. 
 

Accessing the CMD-Server over a WAN 

 
The CMD-Server can be accessed from anywhere in the world if the LAN to which it is 
connected is configured to allow in-coming traffic. There are generally two ways that this can be 
done. The easiest (but less secure) approach is to setup the router that communicates with your 
ISP (Internet Service Provider) to use Port Forwarding of all HTTPS services so they are sent to 
the IP address of the CMD-Server. A much more secure, but significantly more difficult 
approach is to use VPN tunneling. The instructions for implementing a VPN tunnel go beyond 
the scope of this document. For detailed information please visit your router manufacturer’s 
website and consult with your network administrator on the best approach for your needs. 
 
 

Содержание UltraSensor CMD-2

Страница 1: ...Detail 23 Monitor Screen 23 View Log File 25 Configure Alarm Mass Threshold Sensitivity 26 Logout 26 Software Updates 26 Sensor Specifications 27 Integrating the CMD Server 24 with your network 28 Ch...

Страница 2: ...he only limitation is that the sensor cannot be covered with sheet metal or a dense metal mesh material The radial range of the sensor is 22 to 25 feet 6 5 to 8 meters and it covers an elliptical patt...

Страница 3: ...45cm by about eighteen inches 45 cm deep A four inch 10 cm layer of sand is placed in the hole and the sensor is placed on top of the sand The sensor is then covered with sand about one inch 2 5 cm d...

Страница 4: ...an be connected to and powered from the basic server shown below Other servers are available with additional capacity and dry switches Dry contact connections are provided for each sensor so that alar...

Страница 5: ...ty com Rev 031109 5 Server 8 The CMD Server 8 is a laptop computer system that connects up to 8 sensors to collect and log data This version of the Server is more compact and appropriate for smaller s...

Страница 6: ...raVision Security Inc Salem New Hampshire 03079 USA Tel 866 374 9732 603 685 0303 Fax 603 898 1840 www UltraVisionSecurity com info UltravisionSecurity com Rev 031109 6 USB connection Ethernet connect...

Страница 7: ...cable The cable should be carefully unrolled during installation Kinks in the wire can cause breaks and internal signal reflections which will degrade the signal from the sensor The Ethernet cable ma...

Страница 8: ...er is supplied through the Ethernet cable Each Concentrator Box CB 06 has a separate Ethernet cable that connects it directly to the SERVER and power all through the Ethernet cable POE The SERVER also...

Страница 9: ...hrough the Ethernet cable POE Each Concentrator Box CB 06 has a separate Ethernet cable AND a power cable both parallel cables shown by dashed line that connects it to another CB 06 Box and finally to...

Страница 10: ...p Server can have up to two hubs connected and a maximum of 8 sensors all direct connected 2 CMD Server 24 can deploy 24 sensors 3 CMD Server 48 can deploy 48 sensors 4 Servers can be customized depen...

Страница 11: ...ke note of wire colors and twisted pairs Note Your cable will have its own color combinations What is important is that it is wired the same on both ends and twisted pairs stay together 3 The backshel...

Страница 12: ...3 3 Blue Shield 4 4 Shield 10 Squeeze tabs and return red section into black 11 Screw backshell onto connector It may be easier to temporarily connect to a CMD box while installing the backshell 12 Ti...

Страница 13: ...UltraVision Security Inc Salem New Hampshire 03079 USA Tel 866 374 9732 603 685 0303 Fax 603 898 1840 www UltraVisionSecurity com info UltravisionSecurity com Rev 031109 13...

Страница 14: ...any combination of UltraSensors may be mixed on either Concentrator Box Up to six Sensors are managed by one Concentrator Box To return to the Windows desktop while the UltraSensor software is runnin...

Страница 15: ...rnet Explorer icon on the desktop You may see a Certificate Error page pop up If that happens simply click Continue to this website 3 On the Log in screen User is Admin and the password is generic11 T...

Страница 16: ...x 603 898 1840 www UltraVisionSecurity com info UltravisionSecurity com Rev 031109 16 Create Edit Users 1 Upon successful log in the Option Menu will be displayed Select Setup Users 2 This page is use...

Страница 17: ...6 Configuration Manager will confirm that User has been successfully added 7 Click Continue to return to Create User screen Continue to add Users or if finished select another screen from the menu on...

Страница 18: ...ng drop down box select timed settings for this sensor or always on as default a Use DEFAULT Settings AT ALL TIMES ignore schedule i For Scanning Status Select Enabled ii Enter Alarm Range Threshold M...

Страница 19: ...nd the Stop Hour and Minute Setting can cross midnight i e 11 PM Monday evening Start and 3 AM Tuesday morning Stop vi Enter the Alternate Scanning status Alternate Alarm Range Threshold and Alternate...

Страница 20: ...tandard US feet or Metric meters 6 Select Alarm Logging Options twice per second or once per incident a Choosing once per incident will display and log sensor activity upon state change only After act...

Страница 21: ...hould appear Click Config Set Map scale in the upper tool bar Enter a distance ft for configuring the map The distance will show on the map image Move the distance boxes until the distance matches a k...

Страница 22: ...to add a new switching device Enter the location access code and number of settings Save 5 Edit Device is used to change the access code or number of contacts 6 Use the drop down boxes to configure e...

Страница 23: ...be indicated by a blue icon on the Monitor Screen and recorded in Log Setting noise to either open or closed will cause the activation of an associated system to create another level of awareness Hea...

Страница 24: ...ntation of the facility with Sensors in approximate locations will be displayed 2 The circle surrounding each Sensor displays the approximate total detection area of each Sensor Colored circle icons i...

Страница 25: ...rning events on a yellow background alarm events on a red background and heartbeats on a green background 4 Alarms may be Archived or Dismissed Only Administrative Level users may Archive or Dismiss e...

Страница 26: ...different for each sensor This is normal as each sensor might be buried under different materials or at different depths 5 Subtract 10 from the lowest Mass reading for each sensor and enter this numb...

Страница 27: ...x to twelve inches 15 30 cm 4 Transmitter Frequency Range 200 to 600 MHz 5 POE power and communications Standard IP compatibility 6 Power user supplied 240 120 VAC to the network hub POE is 48 VDC fro...

Страница 28: ...n result in a non functioning product that must be reset by UltraVision s Support personnel For this procedure you will need a router configured with a subnet of 10 10 0 0 and a subnet mask of 255 255...

Страница 29: ...ly two ways that this can be done The easiest but less secure approach is to setup the router that communicates with your ISP Internet Service Provider to use Port Forwarding of all HTTPS services so...

Страница 30: ...gs on the left column if they are not already displayed in the center column Scroll down to use static IP address and enter your network address parameters The Server 8 is preconfigured with an IP 10...

Страница 31: ...Rev 031109 31...

Страница 32: ...operation the application resides in the Windows system tray automatically changing the switch settings as directed by the associated UltraVision Sensor Server Users can use the application GUI to mon...

Страница 33: ...complete the installation steps Running the Application When initialized the UltraVision Remote Switch Device application searches for all Measurement Computing switch devices connected to the PC via...

Страница 34: ...o open the application s Graphical User Interface GUI The GUI allows you to z Monitor and or alter the current state of each switch z Modify the server configuration information z Monitor the applicat...

Страница 35: ...plication is easily removed from the system using the following procedure z If the application is currently running double click on the icon in the system tray to open the application GUI and press Ex...

Страница 36: ...Rev 031109 36 Dry contact switch specifications for Server 8...

Страница 37: ...Rev 031109 37 Dry contact switch specifications for Server 24...

Страница 38: ...mand window will flash on the display Answer OK to any Internet Explorer error messages that you received Icons should return to appropriate colors but sensors may take up to 3 minutes to start respon...

Страница 39: ...ses to use for setting it back as a Server IP Address 10 10 101 254 Subnet Mask 255 255 255 0 Default Gateway 10 10 101 253 DNS Server 10 10 101 253 Alternate DNS is blank Select Obtain IP address aut...

Страница 40: ...isplay all services in a table To correct the switch bank issue optional you don t need to use a remote switch bank A Select Add custom service B In the NAME field type SwitchBank without quotation ma...

Страница 41: ...r to better filter false motion alarms Each of these changes are discussed in more detail below Graphical User Interface GUI Changes The following specific changes were made to the web based Guard and...

Страница 42: ...port for the UltraSensor Monitor API that allows client applications to monitor server activity including server property changes target data and event data Client applications using this API must spe...

Страница 43: ...alarms from being generated unless two or more consecutive motion events occur with a decreasing range i e target moving towards the sensor For example suppose MOTION_COUNT_FILTER is specified as 2 a...

Страница 44: ...hnical Support Email techsupport ultravisionsecurity com Contact information UltraVision Security Systems Inc 16 Northwestern Drive Salem NH 03079 USA www UltraVisionSecurity com info UltraVisionSecur...

Отзывы: