Check and confirm that the Brake Dust Cover is firmly in position. Using
the machine without a dust cover can result in improper brake operation.
NOTE! REPORT AND CORRECT ANY PROBLEMS
IDENTIFIED IN THE PROCEEDING SECTION BEFORE
USING YOUR ULTRA LIFT.
3. Drive System Operation
Lean the machine back and run the Lift Frame up and down twice to confirm
that the drive screw operates smoothly. If significant vibration is observed,
identify the cause and make necessary repairs before using the Ultra Lift.
IV.
ANTI-REVERSE BRAKE
The anti-reverse brake contains two oilite friction bearings and one roller bearing
that are subject to wear and will eventually require replacement. The procedure
for disassembling the brake, examining the components, and reassembling the
brake takes approximately 15 minutes. The first brake inspection should be
conducted after a year of operation and should be repeated at six month intervals
thereafter. Contact your Ultra Lift Dealer or Ultra Lift Corporation for detailed
brake inspection procedures.
-24-
Содержание 1500