Table 4.3 - Troubleshooting (Cont'd)
Motor is Hot, But Starts
When Cool.
Overload protector has opened.
Check supply voltage. Check
excessive pressure at point of
application. Check binding pump
mechanism.
Belt is Noisy.
Worn belt. Pulley misaligned.
Pulley out of round; wobbly.
Replace belt. Adjust tension by the
tensioning screw. Align pulley per
procedure found on in Section 4.4.6
(Gearbox Cover Installation for Pulley
Drive), steps q through u.