CF.440.400.001.IM.0417
ENCORE
®
700 METERING PUMP
33
4.2.2
Cleaning Clogged Solution Tube
Where solution joins water being treated and that water contains
considerable hardness, there may be a deposit formed inside the solution tube
at the point of application. In time, this can completely plug this tube and the
deposit must be removed. The best method is by dissolving the deposit as
described in paragraph 4.2.1. Where this condition is known to exist, clean the
solution tube as a part of routine maintenance.
4.3
Periodic Preventive Maintenance
To minimize unscheduled shut down and ensure maximum service life, perform
periodic maintenance at specifi ed intervals while the equipment is in
satisfactory condition. Table 4.1 lists the intervals, maintenance operation, and the
preventive maintenance kits required. Before starting the work, ensure that the
appropriate preventive maintenance kits are in stock. Refer to Section 6 -
Preventive Maintenance Kits and Spare Parts List for the appropriate
maintenance kit.
NOTE: Although all parts are designed for long service life, it is
recommended that routine maintenance be performed to safeguard against
unexpected downtime.
Table 4.1 - Scheduled Maintenance Index
Interval
Maintenance Operation
Preventive Maintenance Kit
Annually
Replace PTFE diaphragm, PTFE disc
(between diaphragm and back-up ring),
and crosshead bellow seal.
Diaphragm Maintenance Kit
Replace valve sets, which include the
seat, ball, retainer/guide, and O-rings.
Valve Kit
(Double ball valves: 2 kits required)
Lubricate (refer to paragraph 4.3.1).
Bel-Ray Worm Gear Oil 460, (Product
Code 11000), 2 quarts required.
Replace belt.
APS4857
Six Months
For slurry application or other abrasive
chemical, replace valve sets every six
months.
Valve Kit
(Double ball valves: 2 kits required)
Содержание Encore 700
Страница 2: ......
Страница 3: ...ENCORE 700 DIAPHRAGM METERING PUMP MANUAL NO CF 440 400 001 IM 0417...
Страница 6: ......
Страница 8: ......
Страница 16: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP...
Страница 30: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 14...
Страница 70: ......
Страница 72: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 55 AIC3021 DIRECT DRIVE PARTS 440 400 001 010A ISSUE 3 03 17...
Страница 124: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 107...