46
Figure 4-1. Eccentric Shaft Alignment
h. Rotate the eccentric shaft assembly (45) and take the indicator reading
at two locations, 180° apart, and along the eccentric travel of the sheave.
i. Both readings must be the same. If the readings are diff erent, turn the
carrier bearing clockwise or counterclockwise until a point is found
where the readings are the same.
j. If the pump is equipped with detent stroke mechanism, (for manual
Stroke Positioners), turn the carrier bearing clockwise to the nearest
detent.
NOTE: Do not disturb this set position until the knob is secured at zero
scale indication.
k. Apply silicone grease to the O-ring and install it in the groove in the
stroke control housing.
CAUTION: The carrier bearing must not be disturbed while performing
the next four steps.
l. Start the three M6 screws (48), with Nylok
™
patch, in the knob.
m. Position the knob (47) over the stroke control housing with the zero
graduation on the knob lined up with the center line of the stroke control
housing scale, as shown in Figure 4-2.
!