CF.440.400.001.IM.0417
ENCORE
®
700 METERING PUMP
50
NOTE: The proper adjustment of the belt tension is when it stops “fl ap-
ping” while the motor is running. Electrical continuity between the slide
plate and the stand-off plate is necessary.
r. Loosen the set screw (3mm allen wrench) on the motor pulley just
enough so it will not drop.
s. With reference to Figure 4-4, adjust the motor pulley so that there is
a .005"/.010" gap between the belt edge and the pulley surface on the
worm shaft.
Figure 4.4 - Motor Pulley Adjustment
t. Install the rear belt guard to the pump followed by the front belt guard
and screw the two side screws. Make sure that the front belt guard
catches the shoulder washer in front of the pump.
u. Screw the two cap screws that hold the rear belt guard and slightly push
the front belt guard against the shoulder washer and tighten the two cap
screws.
4.5
Troubleshooting
Troubleshooting of the Encore 700 Series Metering Pump consists of procedures
and instructions for repair and/or replacement of subassemblies and components.
The troubleshooting procedures are limited to fault isolation to a defective item.
Potential problems that could be at fault and recommendations for corrective
action are listed in Table 4.3. Procedures are based on potential fault conditions
that may occur under normal pump operation.
Содержание Encore 700
Страница 2: ......
Страница 3: ...ENCORE 700 DIAPHRAGM METERING PUMP MANUAL NO CF 440 400 001 IM 0417...
Страница 6: ......
Страница 8: ......
Страница 16: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP...
Страница 30: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 14...
Страница 70: ......
Страница 72: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 55 AIC3021 DIRECT DRIVE PARTS 440 400 001 010A ISSUE 3 03 17...
Страница 124: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 107...