CF.440.400.001.IM.0417
ENCORE
®
700 METERING PUMP
16
2.1
General Information
To provide satisfactory service, the metering pump must be installed in accor-
dance with the instructions that follow. Operational diffi
culties, lack of accuracy,
and possible damage to the pump mechanism may occur if these instructions
are not followed properly.
2.2
Unpacking
When the pump is unpacked, check all items against the packing list to make
sure that no parts are discarded with the packaging material. Whenever possible,
unpack the equipment at the installation site.
2.3
Mounting the Pump
Pump location is important to the operation of the pump. Select a place that is
dry and that provides a level base for the pump. Allow work space around the
pump for inspection, adjustments, and servicing (refer to Dwgs. 440.400.110.010
or 440.400.110.020). Be sure it is near a power supply and located where the
discharge line may be conveniently run to the point of application. The pump may
be installed with a fl ooded suction arrangement (refer to Dwg. 440.400.110.040).
A carefully considered and correct installation will help provide satisfactory
performance.
When installing the equipment, proceed as follows:
a. Select the appropriate dimension and/or installation drawing to be sure the lo-
cation selected will meet all requirements. Refer to Dwgs. 440.400.110.010,
020, 030, and 040.
b. Mount the pump on the bench, shelf, or level pad on which it will be located.
c. Connect to a power supply matching the characteristics specifi ed on the
motor nameplate and in accordance with local electrical code requirements.
Suffi
cient fl exibility must be provided in the
connection to permit adjustments. Be sure to provide a shut-off switch in
the power supply.
NOTE: Field wiring must conform to local electrical codes.
WARNING: TO AVOID POSSIBLE SEVERE PERSONAL INJURY OR
DAMAGE TO THE EQUIPMENT CONSULT YOUR UGSI CHEMI-
CAL FEED, INC. REPRESENTATIVE IF THE PUMP IS TO BE USED
UNDER CONDITIONS OTHER THAN ORIGINALLY SPECIFIED
OR IF THERE IS ANY QUESTION REGARDING THE SIZE OF
THE DISCHARGE LINE.
!
Содержание Encore 700
Страница 2: ......
Страница 3: ...ENCORE 700 DIAPHRAGM METERING PUMP MANUAL NO CF 440 400 001 IM 0417...
Страница 6: ......
Страница 8: ......
Страница 16: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP...
Страница 30: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 14...
Страница 70: ......
Страница 72: ...CF 440 400 001 IM 0417 ENCORE 700 METERING PUMP 55 AIC3021 DIRECT DRIVE PARTS 440 400 001 010A ISSUE 3 03 17...