10. RIBBON SAVE DEVICE, cont'd.
10.6
Print Unit Assy, cont'd.
Continued!
Label Stop/Black Mark Sensor Replacement, cont'd:
To reassemble the LSS, proceed as follows:
• Thread the cables through the hole in the inner gable.
• Place the inner, lower corner of the bracket into the groove in the
carriage, almost at the innermost end.
• Tilt the bracket up at the outer end and push it inwards so the inner
notch in the bracket engages the carriage.
• Press down the outer end of the bracket, so the snap-lock engages
the outer notch.
• Press the bracket inwards as far as it goes and check that the
bracket is secured by the snap-lock.
• Connect the cable from the lower sensor to P-600 and the cable
from the upper sensor to P-601 on the CPU board.
• Put back the guide plates and printhead.
• Adjust the lateral position of the LSS.
For more information on the LSS, refer to chapter 8.6.
1.
2.
3.
LSS Bracket
Snap-Lock
Carriage
Outer Notch
Inner Notch