UBI EasyCoder 501 – Service Manual
117
17.3
Circuits and Straps, cont'd.
17. CPU BOARD, cont'd.
P-204 – 209 RS 422 Configuration
These straps are used to adapt the RS 422 communication to the
host. Please refer to chapter 18.3 for further information.
Default:
No jumpers fitted.
P-302 In 5V
This strap is used to isolate the +5V power supply from the rest of
the CPU board. The intention is to test the +5V voltage before
connecting the logic, thereby avoiding damage to the circuits due
to a faulty 5V switch.
Jumper fitted:
+ 5V enabled
Jumper removed:
+ 5V disabled
Default:
Jumper fitted
P-604 Emitter Level for Ribbon-End Sensor
Two levels can be selected for the light intensity of the sensor's
emitter:
Jumper fitted:
High Intensity
Jumper removed:
Low Intensity
Default:
N/A
P-607 Emitter Level for Label-taken Sensor (optional)
Two levels can be selected for the light intensity of the sensor's
emitter:
Jumper fitted:
High Intensity
Jumper removed:
Low Intensity
Default:
N/A
Содержание EasyCoder 501 SA