background image

PAGE 11 OF 17 

0921 IH-9560

MENU SETTINGS CONTINUED 

AUTO OFF

Sets the automatic shutoff functionality. 

•  Off = Disabled 

•  1 = Powers off after one minute of no activity. 

•  5 = Powers off after five minutes of no activity.

•  10 = Powers off after 10 minutes of no activity.

END SETUP 

Advances to the next menu or return to top of current 

menu. 

MODE MENU 

THIS MENU ACTIVATES MODES SO THEY WILL BE 

AVAILABLE FOR USE WITH THE MODE BUTTON.

Reset

no, yes

Weigh

off, on

Count

off, on

Percent

off, on

Check

off, on

Totalization

off, on

Density

off, on

Hold

Disp, Peak, Off

End Mode

Exit menu

RESET [

rESEt

]

Reset the Mode menu to factory defaults.

•  No = Not reset

•  Yes = Reset

WEIGH [

WEIGH

]

Set the status.

•  Off = Disabled

•  On = Enabled

COUNT [

Count

]

Set the status.

•  Off = Disabled

•  On = Enabled

PERCENT [

PErcnt

]

Set the status.

•  Off = Disabled

•  On = Enabled

CHECK [

CHECk

]

Set the status.

•  Off = Disabled

•  On = Enabled

TOTALIZATION [

totAL

]

Set the status.

•  Off = Disabled

•  On = Enabled

DENSITY [

SPEC.Gr

]

Set the status.

•  Off = Disabled

•  On = Enabled

HOLD [

HoLd

]

Set the sub-mode.

•  Off = Disabled

•  Peak Hold = Allows the user to capture and store the 

highest stable weight value (>=5d).

•  Display Hold = Allows the user to capture and store 

the first stable weight value (>=5d).

When the stable value is being held on the display,  

the "Hold" icon will blink and the displayed weight will 

not change. Advance to the next menu or return to the 

top of the current menu.

Содержание SCOUT H-9560

Страница 1: ...WARNING SYMBOLS General Hazard Electric Shock Hazard CAUTION Read all safety warnings before installing making connections or servicing this equipment Failure to comply with these warnings could resul...

Страница 2: ...cale RELEASING TRANSPORTATION LOCK Release the red transportation lock by turning the red pointer 90 degrees counterclockwise to unlock See Figure 1 INSTALLING THE WEIGHING PAN For scales with a recta...

Страница 3: ...and connect the AC plug to an electrical outlet See Figure 5 BATTERY INSTALLATION Install the four AA batteries with polarity as shown in the battery compartment See Figure 6 NOTE After powering on th...

Страница 4: ...f Function Initiates an application mode Tare Enter clear a tare value Secondary Function Long Press Extended Press Zero Off Turns off the scale None Units Changes the weighing unit None Mode Allows c...

Страница 5: ...5 6 7 8 9 10 11 12 13 ITEM DESCRIPTION 1 Battery charge 2 Stable weight 3 Negative 4 Center of Zero 5 NET 6 Preset Tare 7 Pointers 8 Kilogram grain 9 Check Weighing 10 Pound Ounce Pound Ounce Symbols...

Страница 6: ...and hold Mode until Count is displayed CLr PW clear average piece weight APW will then display If no APW exists the scale will display PUt 10 proceed to step 5 3 Press No to use the stored APW Proceed...

Страница 7: ...an the Over limit Place the item to be weighed on the scale and press Tare Remove a portion of the item until it is within the Accept range ZERO CHECK Zero check is used when comparing subsequent samp...

Страница 8: ...two modes for the display hold Peak Hold Allows the user to capture and store the highest stable weight value 5d Display Hold default Allows the user to capture and store the first stable weight valu...

Страница 9: ...On Off Totalize On Off Density On Off Hold Disp Peak Off Reset g kg ct oz ozt dwt lb grn hkt sgt twt t tola tical End End End End End End Available units may vary by local regulations Available settin...

Страница 10: ...y graduation is not displayed NOTE If the scale will be used in direct sales to the public the OFF setting must be selected FILTER Set the amount of signal filtering LOW Less stability faster stabiliz...

Страница 11: ...et the Mode menu to factory defaults No Not reset Yes Reset WEIGH WEIGH Set the status Off Disabled On Enabled COUNT Count Set the status Off Disabled On Enabled PERCENT PErcnt Set the status Off Disa...

Страница 12: ...ore turning the scale over remove the pan and pan support if present and set the transportation lock to locked position The scale can be supported using lab jacks or any other convenient method Ensure...

Страница 13: ...8 5 Tare out of range Err 8 6 Displayed value exceeds 999999 possible in Totalization mode Err 8 7 Unknown internal weight position rEF Err Parts counting or percentage error sample weight 1d Scale sh...

Страница 14: ...ocal weights and measures office for more information SEALING After the unit has been verified it must be sealed by the weights and measures official to prevent undetected access to the legally contro...

Страница 15: ...ernal span or linearity calibration Tare Range Full Capacity by subtraction Weighing Units g kg ct oz ozt dwt lb grn Application Modes Weighing Parts Counting Percent Weighing Check Weighing Totalizat...

Страница 16: ...andards of EU Directives 2011 65 EU RoHS 2014 30 EU EMC 2014 35 EU LVD and 2014 31 EU NAWI The complete Declaration of Conformity is available online at www ohaus com ce This product complies with the...

Страница 17: ...erference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Отзывы: