MENU SETTINGS 

The User Menu allows the customizing of scale settings.  

NOTE: Additional sub-menus may be available 
if Interface Options are installed. 

MENU NAVIGATION 

SUB-MENUS

C.A.L

S.E.T.U.P

M.O.D.E

U.N.I.T*

E.N.D

Tare

Menu

Exit

Yes

No/Back

Exit

Long Press  

Enter Menu

Short press  

Accept

Short press  

Go Next/

Prev. menu
Short press  

Exit menu

Span

Lin

Reset

Yes/No

Auxiliary 

Graduation*

On/Off

Filter

Low/Med/High

AZT

0.5/1/3/Off

StableRange

0.5/1/2//5

Backlight

Off/On/Auto

Auto Tare

Off/On/On-acc

Auto Off

Off/1/5/10

Reset

Yes/No

Weighing

On/Off

Counting

On/Off

Percent

On/Off

Check

On/Off

Totalize

On/Off

Density

On/Off

Hold

Disp/Peak/Off

Reset

g

kg

ct

oz

ozt

dwt

lb

grn

hkt

sgt

twt

t

tola/tical

End

End

End

End

End

End

*Available units may vary by local regulations. 

**Available settings may vary by local regulations. 

When the security switch is in locked position  

(See Figure 7), the menu settings are affected as follows: 

•  External calibration function is hidden. 

•  The readability will be reduced by a factor of 10 

or brackets will be displayed around the last digit, 

depending on the model. 

•  The auxiliary graduation menu will be locked. 

•  Units are locked to the current setting. 

•  Stable range locked to 1d.

•  AZT locked to 0.5d. 

•  Zero range forced to 2%. 

•  Filter level is locked to current setting. 

•  Stable only when Print menu locked ON. 

•  Continuous/Interval print cannot be selected.

Figure 7

Unlocked

Locked

Содержание SCOUT H-9560

Страница 1: ...WARNING SYMBOLS General Hazard Electric Shock Hazard CAUTION Read all safety warnings before installing making connections or servicing this equipment Failure to comply with these warnings could resul...

Страница 2: ...cale RELEASING TRANSPORTATION LOCK Release the red transportation lock by turning the red pointer 90 degrees counterclockwise to unlock See Figure 1 INSTALLING THE WEIGHING PAN For scales with a recta...

Страница 3: ...and connect the AC plug to an electrical outlet See Figure 5 BATTERY INSTALLATION Install the four AA batteries with polarity as shown in the battery compartment See Figure 6 NOTE After powering on th...

Страница 4: ...f Function Initiates an application mode Tare Enter clear a tare value Secondary Function Long Press Extended Press Zero Off Turns off the scale None Units Changes the weighing unit None Mode Allows c...

Страница 5: ...5 6 7 8 9 10 11 12 13 ITEM DESCRIPTION 1 Battery charge 2 Stable weight 3 Negative 4 Center of Zero 5 NET 6 Preset Tare 7 Pointers 8 Kilogram grain 9 Check Weighing 10 Pound Ounce Pound Ounce Symbols...

Страница 6: ...and hold Mode until Count is displayed CLr PW clear average piece weight APW will then display If no APW exists the scale will display PUt 10 proceed to step 5 3 Press No to use the stored APW Proceed...

Страница 7: ...an the Over limit Place the item to be weighed on the scale and press Tare Remove a portion of the item until it is within the Accept range ZERO CHECK Zero check is used when comparing subsequent samp...

Страница 8: ...two modes for the display hold Peak Hold Allows the user to capture and store the highest stable weight value 5d Display Hold default Allows the user to capture and store the first stable weight valu...

Страница 9: ...On Off Totalize On Off Density On Off Hold Disp Peak Off Reset g kg ct oz ozt dwt lb grn hkt sgt twt t tola tical End End End End End End Available units may vary by local regulations Available settin...

Страница 10: ...y graduation is not displayed NOTE If the scale will be used in direct sales to the public the OFF setting must be selected FILTER Set the amount of signal filtering LOW Less stability faster stabiliz...

Страница 11: ...et the Mode menu to factory defaults No Not reset Yes Reset WEIGH WEIGH Set the status Off Disabled On Enabled COUNT Count Set the status Off Disabled On Enabled PERCENT PErcnt Set the status Off Disa...

Страница 12: ...ore turning the scale over remove the pan and pan support if present and set the transportation lock to locked position The scale can be supported using lab jacks or any other convenient method Ensure...

Страница 13: ...8 5 Tare out of range Err 8 6 Displayed value exceeds 999999 possible in Totalization mode Err 8 7 Unknown internal weight position rEF Err Parts counting or percentage error sample weight 1d Scale sh...

Страница 14: ...ocal weights and measures office for more information SEALING After the unit has been verified it must be sealed by the weights and measures official to prevent undetected access to the legally contro...

Страница 15: ...ernal span or linearity calibration Tare Range Full Capacity by subtraction Weighing Units g kg ct oz ozt dwt lb grn Application Modes Weighing Parts Counting Percent Weighing Check Weighing Totalizat...

Страница 16: ...andards of EU Directives 2011 65 EU RoHS 2014 30 EU EMC 2014 35 EU LVD and 2014 31 EU NAWI The complete Declaration of Conformity is available online at www ohaus com ce This product complies with the...

Страница 17: ...erference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Отзывы: