background image

PAGE 6 OF 17 

0921 IH-9560

OPERATION CONTINUED

TURNING ON/OFF

To turn on scale, press and hold the Zero button for 

one second. The scale performs a display test and 

momentarily displays the software version before 

entering the active weighing mode. 

To turn off the scale, press and hold the Zero button until 

OFF is displayed.

CALIBRATION OPERATION 

When the scale is operated for the first time, a span 

calibration is recommended to ensure accurate 

weighing results. Before performing the calibration, be 

sure to have the appropriate calibration weights. Ensure 

that the security switch is set to unlocked position.

Press and hold Menu until [

MENU

] is displayed. When the 

button is released, the display will show [

C.A.L

]. Press Yes 

to accept. [

SPAN

] will then be shown. Press Yes to begin 

the span calibration. 

[

--C--

] will be displayed while zero reading is stored. 

Next, the display shows the calibration weight value. 

Press the No key to toggle the value. Place the specified 

calibration weight on the pan. [

--C--

] will be displayed 

while the reading is stored. The display will show [

donE

if the calibration was successful. The scale will return to 

the previous application mode and is ready for use.

WEIGHING MODE

This mode is the factory default setting. 

1.  If needed, press and hold Mode until [

WEIGH

] is 

displayed. 

2.  If required, place an empty container on the pan 

and press Tare

3.  Add sample to the pan or container. The display will 

show the weight of the sample.

COUNTING MODE

This mode counts large numbers of items based on the 

weight of a reference count. 

1.  If required, place an empty container on the pan 

and press Tare

2.  Press and hold Mode until [

Count

] is displayed.  

[

CLr.PW

] (clear average piece weight, APW) will then 

display. If no APW exists, the scale will display [

PUt.10

], 

proceed to step 5. 

3.  Press No to use the stored APW. Proceed to step 7. 

4.  Press Yes to establish an APW. 

5.  The scale will then display the sample size, i.e.  

[

PUt 10

]. Press No or Back to toggle the choices  

(5, 10, 20, 50 or 100). 

6.  Put the indicated number of pieces on the pan and 

press Yes to calculate the APW. The display will show 

the piece count. 

7.  Add additional pieces until the desired count is 

reached. 

8.  To clear the stored APW, press and hold Mode 

until [

Count

] is displayed. Press Yes when [

Clr.pW

] is 

displayed. 

NOTE: Press Function to view the current APW.

PERCENT MODE 

This mode measures the weight of a sample as a 

percentage of a reference weight. 

1.  If required, place an empty container on the pan 

and press Tare

2.  Press and hold Mode until [

PErcnt

] is displayed.  

[

CLr.rEF

] will then display. If no reference weight 

exists, the scale will display [

Put.rEF

]; proceed to 

step 5. 

3.  Press No to use the stored reference weight and 

proceed to step 6. 

4.  Press Yes to establish a new reference. Scale will now 

display [

Put.rEF

]. 

5.  Add the desired reference material to the pan or 

container. Press Yes to store the reference weight. 

The display will show 100%. 

6.  Replace the reference material with the sample 

material. The display will show the percentage of the 

sample compared to reference weight. 

7.  To clear the stored reference, press and hold Mode 

until [

PErcnt

] is displayed. Press Yes when [

CLr.rEF

] is 

displayed. 

NOTE: Press Function to view the current 
reference weight.

CHECK MODE 

Use this mode to compare the weight to a target weight 

range. The scale supports positive, negative and zero-

check weighing. 

CHECK WEIGHING 

Use this mode to compare the weight of items to a 

target weight range. 

Содержание SCOUT H-9560

Страница 1: ...WARNING SYMBOLS General Hazard Electric Shock Hazard CAUTION Read all safety warnings before installing making connections or servicing this equipment Failure to comply with these warnings could resul...

Страница 2: ...cale RELEASING TRANSPORTATION LOCK Release the red transportation lock by turning the red pointer 90 degrees counterclockwise to unlock See Figure 1 INSTALLING THE WEIGHING PAN For scales with a recta...

Страница 3: ...and connect the AC plug to an electrical outlet See Figure 5 BATTERY INSTALLATION Install the four AA batteries with polarity as shown in the battery compartment See Figure 6 NOTE After powering on th...

Страница 4: ...f Function Initiates an application mode Tare Enter clear a tare value Secondary Function Long Press Extended Press Zero Off Turns off the scale None Units Changes the weighing unit None Mode Allows c...

Страница 5: ...5 6 7 8 9 10 11 12 13 ITEM DESCRIPTION 1 Battery charge 2 Stable weight 3 Negative 4 Center of Zero 5 NET 6 Preset Tare 7 Pointers 8 Kilogram grain 9 Check Weighing 10 Pound Ounce Pound Ounce Symbols...

Страница 6: ...and hold Mode until Count is displayed CLr PW clear average piece weight APW will then display If no APW exists the scale will display PUt 10 proceed to step 5 3 Press No to use the stored APW Proceed...

Страница 7: ...an the Over limit Place the item to be weighed on the scale and press Tare Remove a portion of the item until it is within the Accept range ZERO CHECK Zero check is used when comparing subsequent samp...

Страница 8: ...two modes for the display hold Peak Hold Allows the user to capture and store the highest stable weight value 5d Display Hold default Allows the user to capture and store the first stable weight valu...

Страница 9: ...On Off Totalize On Off Density On Off Hold Disp Peak Off Reset g kg ct oz ozt dwt lb grn hkt sgt twt t tola tical End End End End End End Available units may vary by local regulations Available settin...

Страница 10: ...y graduation is not displayed NOTE If the scale will be used in direct sales to the public the OFF setting must be selected FILTER Set the amount of signal filtering LOW Less stability faster stabiliz...

Страница 11: ...et the Mode menu to factory defaults No Not reset Yes Reset WEIGH WEIGH Set the status Off Disabled On Enabled COUNT Count Set the status Off Disabled On Enabled PERCENT PErcnt Set the status Off Disa...

Страница 12: ...ore turning the scale over remove the pan and pan support if present and set the transportation lock to locked position The scale can be supported using lab jacks or any other convenient method Ensure...

Страница 13: ...8 5 Tare out of range Err 8 6 Displayed value exceeds 999999 possible in Totalization mode Err 8 7 Unknown internal weight position rEF Err Parts counting or percentage error sample weight 1d Scale sh...

Страница 14: ...ocal weights and measures office for more information SEALING After the unit has been verified it must be sealed by the weights and measures official to prevent undetected access to the legally contro...

Страница 15: ...ernal span or linearity calibration Tare Range Full Capacity by subtraction Weighing Units g kg ct oz ozt dwt lb grn Application Modes Weighing Parts Counting Percent Weighing Check Weighing Totalizat...

Страница 16: ...andards of EU Directives 2011 65 EU RoHS 2014 30 EU EMC 2014 35 EU LVD and 2014 31 EU NAWI The complete Declaration of Conformity is available online at www ohaus com ce This product complies with the...

Страница 17: ...erference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Отзывы: