PAGE 14 OF 17
0921 IH-9560
LEGAL FOR TRADE
TECHNICAL DATA
When the scale is used in trade or a legally controlled
application it must be set up, verified and sealed
in accordance with local weights and measures
regulations. It is the responsibility of the purchaser to
ensure that all pertinent legal requirements are met. As
the requirements vary by jurisdiction, the purchaser is
advised to contact local weights and measures office
for instructions about putting the scale into service.
SETTINGS
Before verification and sealing, perform the following
steps:
1. Verify that the menu settings meet the local weights
and measures regulations.
2. Units menu should be reviewed. Verify the units
turned on are permitted by the local weights and
measures regulations.
3. Perform a calibration.
4. Set the security switch to the locked position.
VERIFICATION
A weights and measures official must perform the
verification procedure. Contact the local weights and
measures office for more information.
SEALING
After the unit has been verified, it must be sealed by the
weights and measures official to prevent undetected
access to the legally controlled settings. Before sealing
the device, ensure that the security switch is in the
locked position. (See Figure 9)
If using a wire seal, pass the sealing wire through the
holes in the security switch and bottom housing.
(See Figure 9)
If using a paper seal, place the seal over the security
switch and bottom housing. (See Figure 9)
Figure 9
Unlocked
Locked With Paper Seal
Locked With Wire Seal
Equipment Ratings: Indoor use only
Altitude: Up to 6,560 ft
Operating temperature range: 41°F to 104°F
Specified temperature range: Refer to tables on
page 15
Relative humidity: 10% to 80% at 88°F, decreasing
linearly to 50% at 104°F, non-condensing
Power: AC power adapter input 100-240V 50/60 Hz and
output 5 V DC 1 A (for use with certified or approved
power supply, which must have a SELV and limited
energy circuit output), or 4 AA batteries
Main supply voltage fluctuations: Up to +/- 10% of the
nominal voltage
Pollution degree: 2
Installation category: II