46
www.turck.com
• 1-800-544-7769 • Fax:
(763)
553-0708 • TURCK
• Minneapolis,
MN
55441
www.turck.com
• 1-800-544-7769
• Fax: (763) 553-0708
• TURCK • Minneapolis, MN 55441
PB
TURCK
RM-89
DeviceNet Object (03
hex
) (continued)
DeviceNet Object Class Attributes
The only supported Class attribute is 1 and it returns the revision number of the definition of the object . Because the RM-89
implements the CIP revision 2, this attribute will always return a value of “2” .
DeviceNet Instance Attributes
Table B .4 Available DeviceNet Instance Attributes
Ser-
vice
Service
Code
Class
Instance
(decimal)
Attribute Length
(bytes)
Data
Get
Set
0E
10
3
1
1
1
MAC ID
(USINT data type)
Get
Set
0E
10
3
1
2
1
BAUD_Rate
(USINT data type)
Get
Set
0E
10
3
1
3
1
BOI: Bus-off Interrupt
(BOOL data type)
Get
Set
0E
10
3
1
4
1
Bus-off Counter
(USINT data type)
Get
0E
hex
3
1
5
2
Byte 1: Allocation Choice Byte
Byte 2: MAC ID of Master
Get
0E
hex
3
1
6
1
MAC ID Switch changed since last
power up? (BOOL data type)
Get
0E
hex
3
1
7
1
BAUD_Rate switch changed since
last power up? (BOOL data type)
Get
0E
hex
3
1
8
1
Actual value of MAC ID switches
(USINT data type)
Get
0E
hex
3
1
9
1
Actual value of BAUD_Rate switches
(USINT data type)
0 = 125 kHz
1 = 250 kHz
2 = 500 kHz
3 = Read from Flash Memory
Содержание DeviceNet RM-89
Страница 1: ...USER MANUAL MA1007 REV B Published 4 15 2015 RM 89 DeviceNet Resolver...
Страница 14: ...14 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 TURCK RM 89 Notes...
Страница 38: ...38 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 TURCK RM 89 Notes...