www.turck.com
• 1-800-544-7769
• Fax: (763) 553-0708
• TURCK • Minneapolis, MN 55441
25
Adding the RM-89 to a Scan List
The RM-89 can be read with explicit messaging, but using the I/O messaging available with the DeviceNet scanner is far
more efficient . I/O messaging is similar to implicit messaging available with RSLogix 5000 platforms in that the data transfer
will occur automatically between the scanner and RM-89 once it is configured . Data from the scanner will also be updated
automatically in your PLC .
The DeviceNet scanner must be added to the network before it can be configured . Refer to the documentation that came
with your scanner to add it to your network . The 1756-DNB is used in this example .
Once the scanner is added to the network, double click on it to open its Properties window . The Scanlist,
Input
, and
Output
tabs are the most important when configuring the RM-89 .
Scanlist tab
Figure 3 .4 shows the Scanlist tab before any devices are added to the scan list . To add the RM-89, simply click on the device to
select it and then click on the [>] button .
Once added you can:
• Change the
Electronic Key
: parameters to control which devices can be used to replace the RM-89 in the
network .
• Click on the [Edit I/O Parameters] button to change how the RM-89 responds to the three different
communication methods and what data is transferred .
Figure 3 .4 Scanlist Tab
Содержание DeviceNet RM-89
Страница 1: ...USER MANUAL MA1007 REV B Published 4 15 2015 RM 89 DeviceNet Resolver...
Страница 14: ...14 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 TURCK RM 89 Notes...
Страница 38: ...38 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 TURCK RM 89 Notes...