When connecting PC directly, it's need to use cross cable. Otherwise using HUB module, it's no need
to use cross cable.
The way of connecting PC directly is as follows.
It's need to set IP address and subnet mask to your PC.
Set IP address to 192.168.1.10, and subnet mask to 255.255.255.0, for example.
about the way of setting address to your PC, see your PC manual.
Select MS-DOS prompt and access command "ping" in MS-DOS prompt.
C:¥Windows>ping 192.168.1.55
Pinging 192.168.1.55 with 32 bytes of data:
Reply from 192.168.1.55: bytes=32 time=2ms TTL=255
Reply from 192.168.1.55: bytes=32 time=1ms TTL=255
Reply from 192.168.1.55: bytes=32 time=1ms TTL=255
Reply from 192.168.1.55: bytes=32 time=1ms TTL=255
C:¥Windows>
If replies are listed above, physical connection is correct.
If physical connection is not correct, communication replies are these.
C:¥Windows>ping 192.168.1.55
Pinging 192.168.1.55 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Request timed out.
C:¥Windows>
In this case please retry the connection again after confirming the cable connection.
Once you check connection is correct, enter new IP address and new telnet port NO of NCT08-02.
(If default NO is OK, you don't have to do this operation.)
Default IP address is 192.168.1.55, and default port NO is 7777.
IP address must to be changed according to your network system.
If there is no need to change port NO, you may use NO 7777.
If you need to change port NO, the recommended port is NO. 10000 to 10999.
In Windows screen display
START → Specify the file name and run, file name is
2-2-2.Changing setting condition for net-work
5/15