NCT08-02 COMMAND TABLE (To: LAN, USB)

COMMANDS

CONTENTS OF COMMANDS

    DETAILES OF COMMANDS

ALM?

alarm read

inquiry the contents of overflow

CLAL

clear all

clear timer and 8 channel counters

CLPC

clear preset counter

clear preset counter (CH7)

CLTM

clear timer

clear timer

CLCTxx

clear counter xx

clear counter channel xx

xx:00-07

CLCTxxyy

clear counter xx to yy

clear counter channel xx to yy

xx、yy:00-07

CPR?

counter preset data read

read preset count value

reply 8 digit number in decimal (unit Kcts)

(example:00010000)

CPRF?

counter preset data read

read preset count value

reply 8 digit number in decimal (unit cts)

(example:00010000)

CTR?xx

counter xx read

read channel xx count value

xx:00-07

reply 10 digit number in decimal

CTR?xxyy

counter xx to yy read

read channel xx to yy count value  xx、yy:00-07

reply 10 digit number in decimal

 space separated data

DSAS

disable auto stop

disable to automatically stop

(It means count on until STOP command)

ENCS

enable counter stop

enable to counter stop

ENTS

enable timer stop

enable to timer stop

MOD?

mode read

inquiry the mode

RDAL?

read all counter and timer

read all counter and timer

SCPRdddd・・・・

set counter preset data

set preset data to counter (unit Kcts)

SCPRFdddd・・・・

set counter preset data

set preset data to counter (unit cts)

TPR?

timer preset data read

read preset timer data (unit ms)

TPRF?

timer preset data read

read preset timer data (unit μs)

STOP

stop counter

deactivate counting action

STPRdddd・・・・

set preset counter to dddd・・・・

set preset timer value (unit ms)

STPRFdddd・・・・

set preset counter to dddd・・・・

set preset timer value (unit μs)

STRT

start counter

start counting action

TMR?

timer read

read timer value

VER?

version information read

read firmware version information

REST

reset and start

set the unit restart (It's same as power on sequence)

FROM?

using ROM number read

read program ROM number inside

FROM0,FROM1

choose ROM 

set program ROM number to activate

It's valid after RESET or power on sequence.

FLG?x

read internal flag

read internal state flag inside

1/15

Содержание NCT08-02

Страница 1: ...i Pre 300 0013 Japan Phone 81 0 29 832 3031 Fax 81 0 29 832 2662 URL http www tsujicon co jp APPLICATION OF ELECTRONIC DEVICES TSUJI ELECTRONICS CO LTD 3739 Kandatsu machi Tsuchiura city 8CH COUNTER T...

Страница 2: ...eans count on until STOP command enable counter stop enable to counter stop enable timer stop enable to timer stop mode read inquiry the mode read all counter and timer read all counter and timer set...

Страница 3: ...t and clear commands for counter and timer Read out and clear commands for all counter and timer Read out and clear commands for all counter Read out and clear commands for timer Communication command...

Страница 4: ...del of NCT08 01 The commands are almost the same of the NCT08 01 The preset value is round down to multiple number of eight It shows the beginning of count action LED ON means the counter gate open In...

Страница 5: ...vel for each channel Please confirm the signals are between the permitted level 12mA 36mA 1 4mA 20mA 0 The input impedance is 50 so the voltage level will be 0 6V 1 8V 1 and 0 2V 0 To control this one...

Страница 6: ...m 192 168 1 55 bytes 32 time 1ms TTL 255 If replies are listed above physical connection is correct If physical connection is not correct communication replies are these In this case please retry the...

Страница 7: ...play Then select 1 push return push return push return enter port address of then push return Default port NO is if you need to change this number recommended port number is 10000 to 10999 push return...

Страница 8: ...ections specify the folders of downloaded driver software When the driver software installs are done open the Control Panel START Control Panel click the System icon Then property display of system ap...

Страница 9: ...nal When gate signal goes L counting action stopped during L period When gate signal goes L LED lamp is OFF during this period LED lamp goes ON during gate signal is H when counter starts When gate si...

Страница 10: ...Setting and readout of preset counter Type of command dddd To set preset value dddd in decimal to preset counter Unit is Kcts Maximum value is 281 474 976 710 Kcts dddd To set preset value dddd in de...

Страница 11: ...Reply 123456 Reply data is 8 digit decimal value 4294967000 If reply data is over 8 digit the digit is as the timer digit Unit is s Type of command STRT Enable counter start Type of command ST Enable...

Страница 12: ...is as the value digit Type of command To clear timer value Inquiry of over flow count data Type of command To inquiry about data overflow timer and count data Reply example over Timer is in normal ov...

Страница 13: ...er number 4 overflow Reply data 04 mean Counter number 6 overflow Reply for command FLG 2 Time up carry monitor RUN OUT COUNTER ON Timer overflow Counter number 7 overflow TTL GATE TTL STOP TTL START...

Страница 14: ...ower line of NCT08 02 Turn on power of NCT08 02 again the firmware version will be new Without turning off power line it gets start by RESET command There are two pieces of flash ROM FROM loaded insid...

Страница 15: ...a 100 times total disable period is 120ns 100 12 s Disable period for each reading access is always same 120ns Counter and timer stops simultaneously you d better to read data by minimum command When...

Страница 16: ...p counting action continues until stop trigger or STOP command Enable to count or not for all channels and timer Goes to count mode by open or H level In count mode LED turn on green In count mode sig...

Отзывы: